Laserfiche WebLink
COMPUANCE <br />REQUIRED <br />INsPEcnoN IMPORTANT: Disregard topics that don't describe your building or equipment. 00 NOT <br />APPROVED place checks In the two left columns. <br />} ❑ Airflow from habitable rooms to whole -house fan ensured by undercut doors or grills (VIAQ, S. 302.6.4) <br />❑ M LoosefIII insulation OK If (S.502.1.4.5): <br />❑maximum ceiling slope L3 in 12 <br />M 30" of clear distance from top of bottom chard to underside of roof sheathing at the roof ridge. <br />�[ ❑ mil black polyethylene ground cover, lapped 12" at joints and to foundation wall <br />❑ UClearances shall meet listed minimums between insulation and (S.502.1.4.3): <br />r3 chimney ❑ Non -IC rated recessed lights: 1/2" to combustables, 3" to insulation. <br />❑ gAttic <br />ic hatch shall be insulated to required ceiling R-value and is weatherstripped (S.502.1.4.4) <br />❑ access shall have wood dam or equivalent to retain loose fill Insulation in attic (S. 502.1.4.4) <br />II exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />❑ 7 Service hot & cold water piping shall be Insulated to R-3 (S. 503.11) <br />❑ JFRIeadlly <br />ervice recirculation hot water piping shall be insulated to Table 5-12 levels. <br />El hemostat provided for each HVAC system with range of 55-75' F.(heating) (S.503.8.1.1). <br />❑ accessible, automatic or Manual means provided to restrict or shutoff Heating Input to each <br />zone or floor during periods not requiring heat (S. 503.8.3.1). <br />r ❑ r Controls for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br />❑ 2 Mechanical ventilation systems shall have proper timers, and/or switches (S. 302.3). <br />❑ a Mechanical ventilation ducts shall have Insulation x R-4 in unconditioned spaces (VIAQ, S. 302.5) <br />JM ❑ Mechanical supply ducts In conditioned spaces shall have z R-4 insulation (VIAQ, S. 302.5) <br />❑ s upply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />❑ Supply and return air ducts shall have sealed duct joints in unconditioned spaces (S. 503.10.2). <br />❑ x HVAC plenums, supply, and return air ducts shall have R-8 insulation (Table 5-11, All options) <br />❑ Electric water heater(s) shall have (S. 504.2.1, 504.3, 504.4) <br />Aseparate power shutoff t':1 1987 NAECA Lable on tank <br />prnonoompressible R10 pad{unheated spaces only) ;' Temperature setting s 120 F. <br />(� ❑ 9 Showers and lavatories shall limit flow to s 3.0 gallons/minute (S. 504.8.1). <br />❑ ❑ Swimming pool(s) (S. 504.5) shall have: <br />❑readily accessible ONIOFF switch (pump, heater) ❑ Pool cover ❑ Piping insulated to S. 503.11 <br />❑ ❑ r Fireplace(s) (VIAQ, S. 402.3) shall have: <br />❑ 6 square inch combustion air supplyduct w/ operable damper, directly connected to the fire box <br />p Tight fitting glass or metal doors; or flue draft Induction fan. ❑ Tight fitting flue damper. <br />O O 2 Solid fuel burning appliance(s) (VIAQ, S. 402.2) shall have: <br />o Tight fitting glass or metal doors <br />❑ Outside combustion air source directly connected to the fire box <br />❑ Exception: Non -direct, 4" diameter, dampered, combustion air source: allowed only for (1) new stove <br />installations in existing homes where obstructions preclude direct combustion air, or (2) Central <br />heating systems located in unheated spaces. <br />❑ ❑ a Three month, etched track, radon monitor, printed instructions, and an information sheet shall be <br />supplied by the builder to each single family dwelling and to each ground floor unit of multi -family dwellings <br />(VIAQ, S.502.2.1). <br />WSEC Final phase requirements: <br />Inspected by Date <br />Page 6 of 6 <br />