Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard #601. <br /> � Connect�ide sewer per City Standard#'s 601, 602, 604. <br /> C� <br /> 6,, Connect all rooftop downspouts to th�side sewer. <br /> 7. Connecl rooftop downspouts to the drainage system provided for this lot. <br /> 8. Rooftop runoft must be discharged to a roof downspout infiltration system per City of Everett Storm <br /> Manual 3-2.6.2. The approxim2te size lrench is 3.5'wide, 2'deep and 25'iong. See attachment for <br /> more details. <br /> ;� <br /> �y:,' The conlractor musl meel wilh lhe Public Works Inspector to discuss potential drainage routing prior lo <br /> beginning lhe project. <br /> �i� Install erosion control measures as determined by the Public Works inspector, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> 71. Inslall erosion conlrol measures per City of Everett Standards for small parceis <br /> ��� <br /> 2. . Remove erosion control measures upon compietion of the project prior to final approval of the permit. <br /> 13. All excavated material (rom foundalion, sidewalk and driveways shall be hauled to an approved, <br /> permitled site. No wasting of material is allowed on lhis building lol. <br /> o` <br /> 14.;� No dir:, mud, recks or debris to be tracked unto roadway. <br /> 15� No building materiais to be slacked on sidewalks and sidewalks to be kepl clean and open for <br /> pedes�rian travel. <br /> C1G` Adjusl waler meter box 1"above sidewalk grade. <br /> �7� Remove and replace curb, guller and sidewalk as per Ciry o( Everett Standard Plan #'s 305A 8 306 on <br /> this proposal's frontage as direcled by the Public Works Inspeclor(i.e. all unused driveways and any <br /> broken or damaged area must be replaced). <br /> 18. Install a Type I concrete driveway per City of Everetl Standard G307. <br /> �19..� Pave driveway from the front property line out lo the street paving. <br /> 20. Contact the Water District for connecting provisions for this building's water and <br /> sewer services. <br /> ����_ catcl�asin as per City Stan�ar�a� ith a gas tra er Standar #4'10 '�e auir d for the <br /> "� parkingare'a�--'��� � <br /> C22; If a sewer pump system is to be insfalled, the pressure line niust discharge into a private manhole, lhen <br /> � gravil; �low across the public ric�hl-of-way. <br /> 23. A sprinkler syslem is required for this building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> Z/� <br /> v <br /> P';�Comn�•nts <br />