My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2620 GRAND AVE C&D 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
2620
>
2620 GRAND AVE C&D 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2017 10:01:27 AM
Creation date
2/21/2017 11:15:27 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2620
Unit
C&D
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ <br />�� � <br />;��T, ' i <br />� <br />July 28, Zo14 <br />Mr. Allen Campbell <br />9117 lOth Ave SE <br />Everett, WA 98208 <br />Project Townfiouses <br />Job Address: 267_0 Grand Ave <br />Plan Review: C1406-008 and C1406-Oi. <br />RE: Correctiors Letter <br />{Units A, B, C, D) <br />Sent ui� e-mail <br />���6 � I`� _—...J <br />Dear Mr. Campbell, <br />In response to the application for a conslruction permif, your plans have been exam?ned and <br />you are advised that lhe issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions ur additions may be <br />required by other departments �such as Utilities, Planning, Public Works, or Fire). <br />In order for the processing of y��ur application to continue, it will be necessary to provide the <br />Building Division with two sefs c revisions (and one new set of 11" by 14" plans) m(lecting the <br />corredions requested. Please prepare a response letter showing where each item in this <br />correction letter is addressed on the plan set. <br />Upon resubmittal of the drawings, your application will be given prioriry and plan review will <br />recommence. <br />General <br />i/ i. Finished floor elevations and roof heights, referenced fo the finished grade site <br />elevations, should be shown on the building drawings, referencing the final gradi�g <br />plans. The sitc plan and buildin9 plans are inconsisfent, and both are missing required <br />building elements. The public Works permit has not yct been submitted. <br />a. lhe final graded site slope and dimensio7s (or paviny, building entrances, stair;, <br />and access from the alley parking should be shown consistenUy on Ihe drawings. <br />�?.l Please revise the architedurai plan drawin9s to show th� same buildings as the >ite <br />plan. The unil references on the plans (A through b) should also be shown consistently. <br />,/3. Please revise the architecturai plan drawings to show the revised location of the <br />buildings on thc lot. All drawings shall be drawn to scalc. <br />�Q: Thc buildiny code refcrences and requiremen[s for UniCs C and D(IBC/IMC) arc missing <br />from the submittal. The only references shown are for Units A and B(IRC). <br />a. Each sef o( plans and details should show specific requirements for minimum <br />code compliance for eitherthe IBC or IRC. <br />b. ihe reference to plumbing fixtures on the cover page should be removed, since <br />it is referencing seclions not adopted by WA State. The UPC determines the <br />minimurn required fixture dimensions. <br />C� �� <br />�- <br />
The URL can be used to link to this page
Your browser does not support the video tag.