Laserfiche WebLink
�1 <br />Richard Parfitt <br />Page 2 <br />April 12, 1979 <br />1. Ceiling in bedroom is falling down and has hole in it. <br />2. There shall be proper outside venting for dryer. <br />3. Baseboard heater falling off the wall. <br />4. Baseboard heater wirin4 must be protecteci Uy pipinc7. <br />5. All broken windows must be repaired, <br />6. Bedroom windows shall be brought up to code, 5.7 sq, ct, not <br />more than 44 inches above floor. UHC SecEion 801, <br />7. There shall be back plates on all electrical outlets. <br />8, There shall be ventilation in the kitchen. <br />9, There shall be ventilation in the batl7room. <br />10. Unlawful faucet fixture in bathtub, There shall bc two <br />grounded utility circuits in the kitchen. <br />11. All el.ectrical 9roundings stiall be Urought up to code. <br />