Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br /> i <br /> , 4. ` Connect side sewer per(.�ry Standerd M801. <br /> / 5./ Connect side sewer per City Standard#'s 601,602,604. <br /> � <br /> 6. Connect ail rooHop downspouts to Ihe side sewer. <br /> � Connect rooftop du�vnspouts to the drainage system provided for this lot. <br /> 8. Rooftop runoff rnust be discliarged lo a roof downspout iniiltralion system per City of Everett Storm <br /> Manual 3-2.G.2. The approximate size lrench is 3.5' �vide, 2'deep and 25'long. See attachmenl for <br /> more details. <br /> 9. The contractor must meet with Ihe Public Works Inspector lo discuss potenlial drainage routing prior to <br /> beginning the projecl. <br /> 10. Install erosion control rneasures as delermined by the Public Works inspector, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> 11. Install erosion control measures per Ciry of Everelt Standards(or small parcels <br /> 12. Remove erosion control measures upon completion of lhe project prior lo(inal approval of Ihe permit. <br /> 13. All excavaled malerial from foundalion, sidewalN and driveways shall be hauled lo an approved, <br /> permilted site. tJu v:asling of materi2l is allowed on Ihis buildmg lal. <br /> 14. No dirl, mud, rocks or debris lo be Uacked onlo road�vay. <br /> ' 15. No building materials lo be slacked ai sidewalks and sider;alks to be kepl clean and open for <br /> pedeslrian travel. <br /> � 1 G. Adjust water meter box 1" above sidewalk grade. <br /> 17. Remove and replace curb, gutler and sidewalk as per City of [verett Standard Plan i�'s 305A & 30G on <br /> this proposal's fronlage as direcled by the Public 1Norks hispeclor(i.e. all unused drive�vays and any <br /> broken or damaged area musl be replaced). <br /> 18. Install a Type I concrele driveway per City of Everett Standard lI307. , <br /> 19. Pave driveway from the front property line out lo Ihe slreet paving. <br /> a.t'/o2 ro .s�c/EUsr 3/ ='� <br /> 20. Conlacl lhe �rc✓,dt7'rO Waler Dislricl for connecling provisions for this building's waler and <br /> sewer services. <br /> 21. A catch basin as per City Slandard Plan 51402 with a gas lrap per Standard Plan�1410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be inslalled, the pressure line must discharge into a privale manhole, then <br /> gravity flow across lhe public right-of-way. <br /> 23. A sprinkler system is required for this building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> FOR PUBLIC WORKS INSPECTION, CALL RANDY AT 425339-7403 I CLIFF AT 425-339-7404 <br /> PWCominents <br /> I , <br />