My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11036 PAINE FIELD WAY 2016-01-01 MF Import
>
Address Records
>
PAINE FIELD WAY
>
11036
>
11036 PAINE FIELD WAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2017 9:32:43 AM
Creation date
2/24/2017 9:32:37 AM
Metadata
Fields
Template:
Address Document
Street Name
PAINE FIELD WAY
Street Number
11036
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DuM Leakage AI'fid�vtt � L ( (����n\ <br /> �V' V <br /> Pertnit#: <br /> Houseaddressorlotnumber: ���Z ���• • �,e1d tlUa.. ��f � <br /> city: �ver�t�' zip: °I�z�`1 <br /> Cond. Floor Area(ft2): I�}b? Source(circle one): Plan Estlmated Measured <br /> ❑ Duct tightness testing is not required for this residence per exceptions listed al the end of Ihis document <br /> Air Handler in conditioned space7 0 yes�no Air Handler present during test7�yes� no <br /> Circle Test Method: Leakage to Outside Total Leakege <br /> Maxlmum duct leakepe: <br /> Post ConsMuetion,totel duct laakegs:(floor area x.OB)_ ��CfM(d�25 Pa <br /> Post Conatruction, leakage to outdooro:(Floor area x .O6)= CFM@25 Pa <br /> Rough•In,total duct leakaga with air handler instatled: (Floor area x.O6)= CFM@25 Pa <br /> Rough-In,totel duct leakag�with air handler not tnstalled: (Floor area x .04)= CFMQ25 Pa <br /> Test Result: �g CFM(a�25Pa <br /> Ring (circle one if applicable): Open 1 Z 3 <br /> Duct Tester Localion: ��i4 Pressure?ap Location:�/.d — <br /> I certify that thesa duct leakaga rates ara accurate and determined using standerd duct testinp protocol. <br /> CompanyName: �o►ner S�on2 Ne.�•es Technician:P�e�Ie Gkd3 <br /> Technicfan Signature: � Q. �.� Date: /Z-6• Z� �Phone Number: 44T •3Q�.40gS <br /> Washington Stete EnsrpyCods rohronce: <br /> 50�.10.]Sealinp.All duds,alr handlere,filter boxes,end buildinp wNtlea used es duds shall be sealed.Joints end seams shall oomply <br /> with Sectlon M7601.3 of lhe Inlemafional Resldenflal Code or BD3.9 0l lhe Infemefional MecM1enlcal Code. Dud tipMnsts teatkp ahall be <br /> conduded W verily thal lhe ducla are sealed.A signed affidavil docunentinp ll�e leq resuRa shall be provWed lo Me�urlsdidbn hevirp <br /> authoAty hy the teslinp egenl.When required by lM bullding o�idal,ms ia.�anan w�,a�aw M ms v�s.snc.a aamme�.un. <br /> Exeeplions: 1.Dud tiphtness tent la not roquirod if the alr hsMbr end ell duGs an lodted wltl�ki condltbnsd apaoe. <br /> 2.Dud lesGnp Is nol requlred if ihe fumace Is a nondiroct vent type eombustbn�ppNena IroGRed M an uncaditbned spaee. <br /> A maximum of siz teel of conneded ducMotk In tM uncondilioned space k eloHed.M addNaW supply end relum duUa <br /> shall be wlthin the conditioned space.Ductt outcide lhe conditbnad space ehall be tealed Mth e meatic lype ducl ssei�nt�nd <br /> inaulated on the ederior wilh R-8 Insulation for above prode ducM and R-5 wetsr roahtenl insulatbn when wilhin e Nab or <br /> earth. <br />