Laserfiche WebLink
� ~ <br /> � <br /> y -, �•-. <br /> p CC <br /> ° y Everett School District W-6884 <br /> � � � 15 June 1990 Page 6 <br /> H <br /> b N h0 <br /> N M <br /> � Z <br /> o � An imported, clean, granular soil free of organics and other deleterious material will <br /> � ;� � therefore likely be needed for use as structural fill during wet site conditions. "Clean" <br /> � y � soils are granular soils that have a fines content of less than 5 percent (by weight) based <br /> y y on the soil fraction passing the U.S. No. 4 Sieve. Material of this type may be <br /> � � N successfully placed and compacted under a wider variety of weather conditions. In <br /> ea r� <br /> � addition to their use as structural fills during wet site conditions, clean soils are required <br /> y for drainaye app lica tions as discusse d su bsequ e n t l y. <br /> Foundation Considerations <br /> In our opinion, isolated or continuous spread footings would provide suitable support for <br /> the proposed additions. Two footing design options are available, with each option <br /> offering a particular allowable soil bearing pressure for a particular footing depth. For <br /> seismic or transient loads this allowabie soil pressure may be increased by up to one- <br /> third. <br /> � `� The first design option would be to extend the footings downward to bear directly on the <br /> native dense to very dense, silty sands (Weathered Till or Glaciai Tili). This would involve <br /> 1 ���� removing the loose, root-laden surficial soils or uncontrolled fill which, based on our <br /> i �� explorations, extended to a depth of roughly 5 feet in the courtyard and up to 2 feet in <br /> the proposed building area southaast of the school. Any deeper, locai zones of soft, <br /> � 1�� loose, organic, or uncontrolled fili soil shouid be removed and replaced with structural fill <br /> compacted to at least 90 percent of the modified Proctor maximum dry density. The <br /> � exposed footing subgrade should be compacted, if warranted by soil conditions, to a <br /> 1� � firm and non-yieiding state. If required, the footing subgrade couid then be raised to the <br /> desired elevation by replacing the excavated soils with properly compacted structural fill, <br /> •• ��-' ' with the footings bearing directly onto this prism of structural fill. We recommend that the <br /> '� structural fill piaced within building areas be compacted to at least 90 percent of the <br /> I modified Proctor maximum dry density. Also, the prism of structural fill should extend <br /> � I���� laterally beyond the edges of the footing a distance equal to the thickness of the fill prism <br /> � below the footing. A maximum allowable soil bearing pressure of 2500 psf (pounds per <br /> square foot) would be appropriate for this t�oting design option. - <br /> We anticipate that t�tal settlements of the foundations should not exceed 1 inch, with <br /> differentiai settlements on the order of one-half of the total. <br />