Laserfiche WebLink
. . � ! , � . , . . , <br /> FIPLI,ANCE <br /> �UIPED � <br /> tNSPecnot�u �MPORTANT:Disregard toplcs that don't describe your huilding or equlpment.oo Nor <br /> pPnoveo p�ace checks In the two Ieft columns. <br /> �� � /� or grilis (VIAa,S.3028.� . <br /> p �o Alrtlow trom habitahie rooms to whole-house fan ensured by d t <br /> p �Looseflll Insulation OK H (S.502.1.4.5): <br /> ,lSlmaximum ceiling slope�3 in 12 <br /> �. 30"of clear distance from top of bottam chord to underside of roof sheathing at the roof�idge. <br /> p s mil black polyethylene ground cover, lapped 12"at joints and to foundatian wall <br /> ❑ �Ciearances shall meet Ilsted minimums hetween Insulation and (S.502.1.4.2): <br /> p chimney p Non-IC rated recessed lights: l/2"to combustables,3"to insulation. <br /> p �ttic hatch shall be fnsulated to required ceil(ng R•value and is weatherstripped (S.502.1.4.4) <br /> p a�s]Attic access shall have wood dam or equivalent to retain loose fill insulation in attic(S.502.1.4) <br /> p �s All exterior doors (exCept 20 minute doors) shall be weatherstripped(S.502.4.4). <br /> p � Service hot&cold water plping shall be insulated to R-3(S.503.11) <br /> p Service recirculatlon dot water piping shall be insulated to Table 5-12 <br /> p hertnostat provided for each HVAC system with range of 55-75' F.(heating) (S.503.8.1). <br /> p o Readlty accessible,sutomatic ar Manual means provtded to restrict or shut-oH Heating input to each <br /> zone or flaor during periods not requireing heat(S. 503.8.3.1). <br /> p � Cantrols for backup heat prahi6ft similtaneausoperation of the p�mary system (S.5032.2(2))• <br /> p s Mechanlcal ventliatlon system shall have timer,dehumidistat, or switch(S.302.3.1). <br /> p Mechanlcal venttlatlon ducts shail have insulation a R-4 in unconditioned spaces(VIAQ,S.3025) <br /> p Mechanlcal suppiy ducts in conditioned spaces shall have 2 R-4lnsulation(VIA�,S.302.5) <br /> p upply ducts shall have volume dampers, or the equivalent,to balance system(S.503.6). <br /> p Supply and return aly ducts shall have sealed duct joints in unconditioned spaces (S.503.10.2). <br /> p HVAC plenums,supply,and retum aly ducts shall have R-8 insulation(Table 5-11, AU options) <br /> p Eledric water heat6r(s) shall have(S.504.3) : $ 1987 NAECA Lable on tank <br /> �separate power,or gas shut-0ft Temperature setting s 120 F. <br /> �noncampressible R10 pad (unheated spaces only) .� <br /> 0 a Showers and tavatories shall tlmit tbw to�allons/minute (S.504.8.1). <br /> � p S1ivlmming pool(s) (S.504.5) shall have: ,S <br /> preadily accessible OWOFF swftch (pwnp, heater) 0 Pooi cover ❑Pfping insulated to S.503.11 <br /> � p � Flreplace(s) (VIAQ,S.402.3) shall have: <br /> 0 6 square inch combustian air supplydud w/operable dampe�,directly connected to the ftre box <br /> p 1"ight fitting glass or metal doors:or flue draft Induction fan. ❑ Tight tiriing flue damper. - <br /> � p 2 SoUd fuel burning appllancE(s) (VIAQ,S.4022) shall have: <br /> p TIgM tttting glass or metal doors <br /> p Outside combustion air source directly connected to the tire hox <br /> p Exception: Non-direct, 4"diameter, dampered, combustfon air source:allowed only for(�Central �ve <br /> installattons in existing homes where obst�uctions preclude di�ect comhustfon air, or(2) <br /> I heating systems located in unheated spaces. <br /> I � supplied by the et�to e chr s nglet famity rdweli ng and oceiach ground floor unRiof mutti-tamiiy dwellings <br /> (VIAQ,S.50221). -��R�Soic�or.a. <br /> WSEC Final phase requirements: pare <br /> lnspected by <br /> Page 6 of 6 <br />