., ' <br />� <br />� <br />� �� <br />The water closet flush controls should be shown mounud on the wide side of t6e <br />water closet area. Secdon 1106.11.5.4 <br />Lavatory drain pipes and hot water pipes should be shown raxssed, insulated or <br />guerded to prevent contact. Secdon 1106.11.7.4 <br />Energy <br />��' The roof insulation should be a minimum of R-21 for the prescripdve path. A <br />component analysis should be submitted in order to use R-19 as shown. Section <br />1322 8c 1330 <br />� The slab-on-grade insulation should be specified as a minimum of R-10. Section <br />1311.5 <br />/3! The opaque doors (man and overhead) should be spe.;ified to have maximum U- <br />factors of 0.60. Table 13-1 <br />�� The storofront glazing system should be specified to have a maximum U-facwr of <br />0.90. Table 13-1 <br />f.� Per Footnote 2 to Table 15-1, ?he warehouse lighting power allowance of 0.50 may <br />be allowed an increase of 16% (based on the approxunate average height of the <br />ceiling above 20 feet). The LPA uf 0.64 as used in the calculations should be <br />clarified. Section 1521 <br />Prepare a response letter showing where each item in this correction lemr is addressed <br />on tl�e plan set. <br />Upon resubmital of the drawings, your application will be given priority and plan rcview <br />will commence. <br />All required submittals shall be of sufficient detail and contain sufficient infotmation to <br />ensure that the proposed structure will be consttucted ia compliance with all Fdopted <br />codes. <br />Sincerely, � <br />�/� v—�� <br />Tony <br />Associate Engineer <br />n:��:ne��n <br />