My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1910 PINEHURST AVE 2018-01-02 MF Import
>
Address Records
>
PINEHURST AVE
>
1910
>
1910 PINEHURST AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2022 2:11:52 PM
Creation date
2/24/2017 3:53:37 PM
Metadata
Fields
Template:
Address Document
Street Name
PINEHURST AVE
Street Number
1910
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 1, 1996 <br />Zeke Farnsworth <br />620 SE Everett Mall Way #350 <br />Everett, WA 98203 <br />Subject: Owner: Chris Coblentz <br />Job Address: 1910 Pinehurst <br />Plan Check No: 52085 <br />Dear Mr. Farnsworth: <br />In response to your application for a construction permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only, additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />1994 Uniform Building Code, as amended by the State of Washington and/or Washington <br />State Energy Code 1995 Edition, unless stated otherwise. <br />In order for the rocessinf, of your application to continue, it will be <br />necessary <br />refl�nthe the Building <br />rec d ngrDivision <br />iv seated With two complete new sets of <br />1. The Washington State Energy Code (WSEC) requires the following minimum levels <br />of insulation: <br />Ceilings R-30 <br />Walls R-19 <br />Floors R-19 <br />The depth of the insulation can at times dictate the size of the framing members, for <br />instance, R-30 insulation is approximately 9 to 10 inches thick and will not fit into a <br />71h inch framing cavity (2x8). The energy code also requires a minimum 1 inch <br />clear air space over insulation in an attic or vaulted ceiling. <br />Provide new rafter and stud size. Specify species and grade of all framing members. <br />2. When the valuation of an addition to a Group R Occupancy exceeds $1,000, smoke <br />detectors shall be installed in accordance with Section 310.9.1.3, 310.9.1.4 and <br />310.9.1.5 of the Uniform Building Code (UBC). <br />Detectors shall be installed in each sleeping room and in the corridor or area giving <br />access to each separate sleeping area. <br />3. The two bedrooms located in the "garage addition" were done without permits. A <br />permit is required at this time for both bedrooms. <br />Both bedrooms shall be provided with natural light and ventilation by means of <br />exterior glazed openings per Section 310.5. <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206) 259-8800 • Fax (206) 259.8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.