C� <br />Evereft Housing Acrthoiity <br />P,1 ay t G, 2012 <br />C� <br />JN 120Q0 <br />Page 5 <br />Depending on the final site yrades, overexcavation may be required below lhe fcotings to expose <br />competent native soil. Unless lean concrete is used to fill an ovarexcavated hole, the <br />overe:ccavation must be at least as wide at the bottom as the sum of the depth of the <br />overexcavation and Ihe footing width. For example, an overexcavation exlending 2(eel below ihe <br />bottom o( a 2-foot-wide footing musl be at least 4 feet wide at the base of the excavafion. If lean <br />concrete is used, the overexcavation need only extend 6 inches beyond the edges of lhe footing. <br />.4n alio�.vable bearing pressure oi 3,000 pounds per square fool (psf) is appropriale for fooCinys <br />supported on competen' soil anC/or structural fill as noted above. A one-third increase in Ihis <br />design bearing pressure may be used �vhen considering short-term wind or seismic loads. Fcr the <br />abo•.e design criteria, it is anticipated that the total posl-construction selllement of footings founded <br />on competent native soil, or on structural fill up to 5 feet �n thickness, will be about one inch, with <br />differenlial settlemenls on the order of one-half inch in 2 distance of 50 feet along a conLnuous <br />footing caith a uniform load. <br />Lateral loads di�e to �vind or seismic forces may be resisted by friction between !he foundation and <br />the bearing soil, or by passive earth pressure acting on the vertical, emhedded portions of the <br />foundation. For the latter ccndition, the foundation must be eilher poured direclly against relatively <br />level, undisturbed soil or be surrounded by levei, compacl f�ll. If the ground in iront of a foundation <br />i> loose or sloping, the oassive earth pressure given above will not be appropriate. We <br />recommend using the follo�.vine, ultimate values for the `ounda:ion's resistance to laleral loading: <br />- ----- - —� <br />I <br />I CoeHi� cier�t o( Friction 0.50 �i <br />�I Passive Earth Pressure 300 pcf � <br />Where: (I) pcf Is pountls per cu61e tool, antl (II) passlve e, rth <br />pressure Is computed using Ihe equlvalent Ould densily. <br />We recommend maintaining a sa(ety factor of at least 1.5 for the foundation's resistance to lateral <br />loading, �vhen using the above ultimale values. <br />P/PE PILES <br />Three-, 4- or G-inch-diameter pipe piles driven wilh a 800- or 1,100-pound hydraulic jackhammer lo <br />the following (inal penetration rales may be assigned the following compressive capacities. <br />3 inches 10 sec!inch 6 sechnch nla I 6 tans <br />4 inches 15 seclinch 10 seGinch 5 sec/inch � 10 ton: <br />6 inches n/a —� 20 seclinch __L 10 sec/inch ___20 ton: <br />Note: The refusal crileria indicated in lhe above table are valid only (or pipe piles that are <br />installed using a hydraulic impacl hammer carried on Ieads lhat allow lhe hammer to sit on <br />GGOTECH CONSULTANTS.INC. <br />