Laserfiche WebLink
� <br />Evereff Housing Autliority <br />hiay 16. 2012 <br />� <br />JN 12080 <br />PaSe 7 <br />The values given above are to be usetl to design only permanent foundation and retaining �valls <br />that are to be backfilled, such as com�entional �valls constructed of reinforced concrete or masonry. <br />It is not appropriate to use the above ear�h pressures and soil unit �veight to back-calculate soil <br />strength parameters for design of olher types of retaining �valls, such as soldier pile, reinforced <br />earth, modular or soil nail walls. We can assist with design of these types of v�alls, i( desired. The <br />passive pressure given is appropriate orly for a shear key poured directly against undislurbed <br />native soil, or for the depth o( level, compact fill placed in front of a retaining or fc�;ndafion �eall <br />The values for friction and oassive resistance are ultimale values and do not include a safet, <br />factor. We recommend a safery faclor of at least 1.5 for overtumin9 and sliding, �r:hen using (he <br />above values lo design the walls. Restrained viall soil oaramelers should be utili�ed fo• a distancc <br />of 1.5 times Ihe wail height (rom comers or bends in lhe walls. Tnis is intended lc rec'.uce fhe <br />amount of cracking that can occur where a�vall is restrained �y a corner. <br />The design values given above do not include the eifects of any hydrostatic pressures behind ihe <br />�valls and assume ihat no surcharges, such as those caused by slupes, vehicles, or adjacent <br />foundalions will be exerted on the �valls. If these conditions exist, ihose pressures should be added <br />to the above lateral soil pressures. Where sloping back(ill is desired behind the �valls, we will need <br />to be given lhe wall dimensions and the slope of the backfill in order to provide the appropriate <br />design earth pressures. The surcharge due to lraffic loads behind a wall can typically be <br />accoi:�ted tor by adding a uniform pressure equai to 2 feel multiplied by the above active fluid <br />density. Heavy constniction equipment shouid not be operated behind retaining and foundation <br />walls within a distance equal lo the height of a wall, unless the walis are designed for the additional <br />lateral pressures resulling trom the equipment. <br />Wall Pressures Due to Seismic Forces <br />The surcharge wall loads that could be imposed by the design earthquake can be modeled <br />by adding a uniform lateral pressure to the above-recommended active pressure. The <br />recommended surcharge pressure is 8H pounds per square foot (ps(), where H is lhe <br />design retention height of the �vall. Using this increased pressure, the safety factor agamst <br />sliding and overturning can be reduced to 1.2 for the seismic analysis. <br />Retaininq Wal! Backfilf end Waterproofinq <br />Backfill placed behind retoining or foundalion walls should be coarse, free-draining <br />struclural fill containing no organic;. This backfill should contain no more than 5 percent silt <br />or clay particles and i�ave no gravei greafer than 4 inches in diametec The percentage of <br />particles passing lhe No. 4 siove should be between 25 and 70 percent. The later section <br />entitlod Drainage Considerations should also be reviewed for recommendations related lo <br />subsurface drainage behind foundation and retaining walls. <br />The purposo of these backfit! requirements is to ensure that the design criterla for a <br />retaining wall are not exceeded because of a build•up of hydrostatic pressure behind the <br />wall. The top 12 to 18 inches of the backfill should consisl of a compacted, relatively <br />impermeable soil or topsoil, or the surface should be paved. The ground surtace musl also <br />slope away from back(illed walls to reduce the potential for surface water to percolate into <br />lhe backfill. <br />It is critical that the wall backfill be placed in lifts and be properly compacled, in order for the <br />above-recommended design earth pressares to be appropriate. The wall design criteria <br />GEO i ECH CONSULTl�NTS, INC. <br />