Laserfiche WebLink
For SI: 1 foot .= 304.& mm, ci .= conunuous insula;ion, int .= intermediate framing. <br />' R-values are minimums. U•factors and SHGC are maximums. �Vhen insuladon is installed in a cavity which is <br />less than the label o� design thicknr.ss of the insulation, the compressed ,.-value of the insulation from <br />Appendix Table A101.a shall not be less than the R-valuc specified in the tab�e. <br />° The fenestration U-factor column excl�des skylights. The SHGC column applies to all glazed fenestration. <br />[xception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 <br />through 3 where the SHGC for such sK,:ights does not exceed 0.30. <br />`"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the con[inuous <br />insulation on the interior o( the wall, or R-21 cavitv insulation pius a thermal break between the slab and the <br />basement wall at the interior of the basement wall. "10/15/2].+TB" shall be permitted to be met with R-13 <br />cavity insulation on the interior of the basement �vail pius R-5 continuous insulation on the interior or <br />exterior of the wall. "10/13" means R-10 continuous insulation on the interior or extericr of the home or R- <br />l3 cavity insulation at the interior of the basement wall. "TB" means thermal break between fioor slab and <br />basement wall. <br />° R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. <br />� There are no SHGC requirements in the Marine Zone. <br />� Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table <br />R301.1. <br />e Reserved. <br />" First value is cavity insulation, second is continuous insvlation or insulated siding, so "13.+5" means R-13 <br />caviry in.;ula.ion pius R-5 continuous insulation or insulated siding. If sVuctural sheathing covers 40 percent <br />or less of the exterior, continuous insulation R-value shall be pe;��utted to �e reduced by no more than R-3 in <br />the locations where struttural sheathing is used to maintain a consistent total sheathmg thickness. <br />' The second R-value applies when more than half ihe insulation is on the interior of the mass wall. <br />' For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R•38. <br />'' Int. (intermediate framing) denotes standar�'• framing 16 inches on center with h��aders insulated with a <br />minimum of R-10 insulation. <br />� Log and solid timber walls with a minimum averege thickness of 3.5 inches are exempt from this insulation <br />requirement. <br />Non(enestration U-factors shall be obtained from measurement, cakulation or an approved source or as <br />specified in Section R402.1.3. <br />