Laserfiche WebLink
. <br /> � � � <br /> /°r/6rL/� /�f��RK'rr <br /> Augusc 14, 1998 <br /> Maurad Layouni <br /> 3211 Norton Avenue <br /> Everott WA 98201 <br /> Subject: Owner: Layouni <br /> ]ob Address: 321 I Norton Avenue <br /> Plan Check No.: 50486 <br /> Dear Mr. Layouni: <br /> In response to your application for a construction permit, your plans have been examined <br /> and you are adv�sed that the issuance of a permit is being withheld for the reasons listed <br /> below. These comments address building issues only, additional revisions or additions <br /> may be required by other departments (such as Utilities, Planning or Fire). All references <br /> refer to the 1997 Uniform Building Code, as amended by the State of Washington and/or <br /> Washington State Energy Code 1997 Edition, unless stated otherwise. <br /> In otYler tor the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of drawings re0ecting the <br /> rnrrections requested. ' <br /> l. U-1 occupancies (private gazages) are limited to one story in height. The second <br /> floor is classified as an "R occupancy". The building code requires one-hour fire- <br /> resistive constiuction on the garage side. Provide 5/8" type 'x' gwb on bearing <br /> walls, ceiling and wrap posts and beams. <br /> 2. Provide new header size species and grade for l6' over head door. <br /> 3. The detail of the garage wall shows an 8' wide, door, 82 5/8" tall, but there is no 8' <br /> door on any other plan or section view. One section view shows a 9' height from <br /> the grade to top plate, another section view shows 8' from slab to top plate. <br /> 4. The center support beam is called out as two different sizes on different sheets. <br /> Specify site species and grade of beam. <br /> 5. Provide detail showing post/beam connection and post/footing connection. Provide <br /> positive connection capable or resisting uplift and lateral displacement. <br /> 6. Provide continuous rim joist. Show on typical section. <br /> 7. Foundations supporting wood are required t� extend min. 6" above the adjacent <br /> finished grade and min. 12" below the finished grade. Show on plans. <br /> CITY OF EVERETT• 3200 Cedar Sireet • EveretL WA 9820t • �425)257•8800• Fax(425)257-8856 <br />