My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
1010
>
1010 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2017 8:20:54 PM
Creation date
2/24/2017 8:20:49 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
1010
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 2i, 1977. <br /> ;h�, f��c. . � , � <br /> GITV OF <br /> everett <br /> arr Hnu . ae9.un�u <br /> rvcn[n. weeHincron <br /> 9P]OI <br /> Capitol Mortgage CO. INSPCCTION OE1'ANTMENT <br /> Lombard & Wal1 <br /> Gverett. Waciiington 98201 <br /> Attn� Lee Devie Re: 1010 Oakes - Electrical Insp. <br /> Dear Mr. Davis: <br /> I made the electrical inspection that I was requested to malce at <br /> 1010 Oakes to determine tlie wiring condition of tlie building The <br /> original knot and tube wiring though inadequate appears to still <br /> Ue ok. Ptuch of the ndditi.onal wiring has been bootlegged in and is <br /> in violation of the code. Thcre is some wiring in tl�e basement <br /> that is liazardous to the point a fire cnn result at any time and <br /> must be corrected. ^'he following requirements are needed to meet <br /> PI1A Standards: ltao addition�il outlets are needed in the kithcen <br /> area, put on a utility circuit, All existing outlets must be grounded <br /> and not on a general lighting circuit. Tl�e fixture in the batl�room <br /> must be grounded along witli l�aveing a grounded receptncle beside the <br /> basin. 'l�o additional oulets are needed in the living room. One <br /> additic�al outlet needed in each upstairs Uedroom. Automatic washer <br /> must be grounded receptacle on a separate circuit. The service is <br /> not a 60 amp rating and several small panels illegally wired in <br /> addition. All of these must t�e removed and all installed in a 100 amp • <br /> on larger panel. There are several places where new wiring has been <br /> added that must be correctly in:;talled. We will be willing tu give <br /> a reasonable time for corrections to be made before requesting •:he <br /> P.U.D, to disconnect the service to avoid a loss by fire. <br /> Yours truly <br /> L J. Dougherty <br /> Electrical Inspector <br /> L7D:eb <br />
The URL can be used to link to this page
Your browser does not support the video tag.