My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1018 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
1018
>
1018 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2017 8:24:02 PM
Creation date
2/24/2017 8:23:54 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
1018
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. w <br /> PU�./C K/O/'�K5 cr <br /> November 7, 1995 <br /> Mr & Mrs. Braden <br /> 1018 Oakes Avenue <br /> Everett WA 98201 <br /> Dear Mr. & Mrs. Braden: <br /> In response to your application for a construc6on permit, your plans have been <br /> examined and you aze advised that the issuance of a permit is being withheld for the <br /> reasons listed below. 1'hese comments address building issues only, additional <br /> revisions or addidons may be required by other departments (such as Utilities, Planning <br /> or Fire). All references refer to the 1994 Uniform Building Code, as amended by the <br /> State of Washington and /or Washington State Energy Code 1995 Edidon, unless <br /> stated otherwise. <br /> 1. Show minimum ceiling height in at least 50% of the room. The ceiling height <br /> for habitable rooms is a minimum of 7'-6". Show that ceiling height for <br /> bathrooms is a minimum of 7'-0" (310.6.1 UBC). <br /> 2. The roof pitch is called out as 2.5:12, but is shown on the elevation at less. <br /> The new roof would be higher than tne existing roof if it is built with the plate <br /> height as shown on the cross secdon. If the new dormer were brought down to <br /> the height of the existing roof at the ridge, the front wall would be <br /> approximately 5' tall. Fiease clarify which type of construcGon is conect <br /> (check window height in dormer addition). <br /> 3. Show how loads are carried through the existing swcture to the foundation. <br /> 4. New wall construction is required to be insulated to minimum R-19 which <br /> requires 2 x 6 framing cavides. Revise plans to show required construcdon. <br /> 5. Provide smoke detectors in all sleeping rooms and in the corridor or azea giving <br /> access to each separate sleeping azea. Detectors shall be installed on each floor <br /> and in basements. Detectors in existing buildings may be solely battery <br /> operated. (310.9 UBC). <br /> CITY OF EVERETT•3200 Cedar Street• Everett, WA 98201 • (206)259-8800• Fax (206) 259-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.