My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1814 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
1814
>
1814 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2017 9:46:50 PM
Creation date
2/24/2017 9:46:39 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
1814
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � . . .- .t . � <br /> . { <br /> everefit � <br /> . ' .- ��\ <br /> ,' . <br /> _ � ,._ ; :,a <br /> . -�.: . <br /> �'<,•__;•.� <br /> ,�� <br /> December 30, 1974 � •� <br /> � fhe Evergreen <br /> ! CITY OF <br /> -_ everett <br /> CITY XALL . s'J�-e1�! � <br /> R.C.F. & P. CO. � av�ncrr. weswu+aron � - <br /> oezo� <br /> 17 H OS 1 O ZIId N�E• IM{�[GTION O[�ARTMCNT , <br /> Bothell, Washington 98011 <br /> Reference: Inspection Request ' <br /> 1814 OaY.es <br /> Everett, Washington � � <br /> Gentlemen: <br /> In reviewing your application for a Building Permit for the <br /> above referenced structure, it was found that the value of <br /> the proposed work exceeds 50 percent of the value of the <br /> building. Therefore, as provided for by Section 104 (]�) of . <br /> the Building Code, the said building shall be made to conform <br /> to the requirements of the code for new buildings. � <br /> The inspection of the building revealed that the building was . <br /> deficient in many areas. The following corrections shall be <br /> complied with as a condition to the issuance of a IIuilding <br /> Permit. <br /> 1. General � <br /> la. All the provisions of the building code for <br /> S. type V-N (frame) 'Group I (single family <br /> dwellings) buildings shall be complied with. <br /> This encludes, but is not limited to the <br /> following: ' <br /> lal. Level all floors.' <br /> 1a2. Construct solid concrete or masonry <br /> foundatiobs as set forth is Chapter 29. <br /> 1a3. Provide under floor ventilation in • <br /> compliance with Section 2517 (c) 6. <br /> 1a4 . Remove and replace all deteriorated <br /> wood. • <br /> 1a5. Remove and replace all wood �in contact <br /> with concrete and masonry with approved <br /> pressure treated wood or foundation <br /> grade cedar. ' <br /> 1a6. Furnish attic ventilation as set forth <br /> in 3205 (c) . <br /> 1a7. Provide an attic access in compliance <br /> ���.ith Section 3205 (a) . <br />
The URL can be used to link to this page
Your browser does not support the video tag.