My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1918 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
1918
>
1918 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2017 10:00:20 PM
Creation date
2/24/2017 10:00:13 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
1918
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 17, 1972 <br /> �he F.�:;::r . ,n <br /> CITY OF <br /> everett <br /> CITY N�LI � 3]Y.eBB] <br /> MacPherson's Inc. ,Realtors EVEqfiTi, WASHIHCTON <br /> 5917 Gvergreen Way °°'°' <br /> INtPCCTION OEPAqTMFNT <br /> Everett, Washington 98203 <br /> Gentlemen: <br /> This will ce:tify that an inspection of the dwelling located at <br /> 1918 Oakes was made by the Housing Inspection Divi.sion and the <br /> structure meets the minimum requirements of the Uniform Building <br /> Code, Volume III except as noted below. <br /> Plumbina• <br /> 1. The water heate: relief valve discharge line is not <br /> full aize. <br /> Z. The clokhes washer waste is not trapped or vented. <br /> There are no air chambers on the water supplies. <br /> Electrical: <br /> 1• 'hoo grounded utility circuits needed in kitchen �nd <br /> dining area, <br /> 2. Additional outlets needed, dining room on soutli wall, <br /> living room on north wall, upstairs bedroom south on <br /> east and west wall, upstairs east bedroom on east wall <br /> and upstairs north room on north wall. <br /> 3. Downstairs bathroom grounded outlet needed, light to <br /> be grounded also. <br /> 4. Upstairs bath outlet to be grounded, light alao. <br /> 5. Washing machine to be on separate circuit. <br /> 6. Hot water tank to be on �F10 wire, <br /> 7. Crawl space H•ir.ing in code violation to Ue corrected. <br /> 8. All wiring to comply with NEC 410-95 (groundin�) , <br /> hfisce�ous: <br /> Comply with condition commitment FIIA Case \•o. 561;258120. <br /> Youra truly <br /> Robert K. Royce, Supervisor <br /> Houaing Inspection Division <br /> By <br /> Houeir.o Inspector <br />
The URL can be used to link to this page
Your browser does not support the video tag.