Laserfiche WebLink
i <br /> �' ' SECTION 3 <br /> I HAZARD DESCRIPTION AND NOZZLE COVERAGE <br /> The R�ri�unnt Fin Hwrd and backshelt broilers,chain broilers,some cheesemelters,and <br /> � charcoal and mesquite wood chunk broilers.Charcoal and mes- <br /> When the cooking eppliances are in use in a commercial iiite wood broilers are further classified as Class•A appliances <br /> I kitchen, such as a resteurent or cafeteria, two things normally since these appliances are on fire in normal operation. <br /> occur. First, the kitchen gets hot, and second, a grease•lilm liances do not require fire protection.These <br /> buildup accumulates on the walis, cabinets, and olher kitchen BPp�elnc�geneeally release only heat andlor water vapor,and <br /> surfaces. are not considered grease-producing appliances. Examples ol <br /> The ezcess heat irom the high vo�ume caoking appliances this type of appliance are steamers,ketlles,and totally enclosed <br /> would meke the kitchen temperature unbearable unless some conveclion ovens. <br /> meMod ot ventilation was provided. For this reason, a sheet- <br /> � metal canopy,or hood,is positioned over the eppliances to cao• Certain terms identifying cooking appliances are too vague lo <br /> ture the rising heated air. A duct from the hood leads to the be used tor fire protection purposes. An example ot a term of <br /> exterior of the building, where the heated air is vented. An this type is "stove." To some individuals, a stove may be an <br /> �� ezhaust ten is provided al the poi�l where the duct ends,to pro• oven,requiring no fire protection.'fo athers,a slove is a ra�ge, <br /> vide suHicient dreR to remove the excess heeted air. �erm9sagrelstlnesome res aurants ba gelQmay be a flaet-surlece <br /> The hood•and-duct system also serves to ceplure a large por• appliance for cooking pancakes,egg �elc. — in other words,a <br /> s <br /> tion ul the grease•laden vapors produced during cooking. As 9�iddle.Other restauranls may call their broilers grills, requinng <br /> the heated, grease•laden air is eccelerated end caoied in the diHerent fire proteclion tha� griddles. Because of the diHerent <br /> hood and duct by the exhaust tan,the grease will setlle out on �ire proteclion requirements ol ihe three general types of <br /> the sheet•metal surfaces, eventually forming a thick Iayer. Fil• apPliances, precision is necessary in the terminology used. <br /> ters are usually installed in an attempt to intercepl some of lhis <br /> ' grease and slow down the accumulation in the hoad and duct. Duct Protection <br /> ' These filters either hold onto ihe grease, or allow it to drain The duct nozzle, PM 806572, is used lor proteclion of the <br /> � away.The space behind the filters,which connecls lo the duct, exhaust ductwork. The tip is slamped with P/N 264379. Eech <br /> is called the plenum.(A plenum is any enclosed chamber for air ducl nozzle accounts lor two flow numbers. Some duct sizes <br /> handling.) Despite the presence ot filters, lhere will slill be an Permit the use of one appliance nozzle, PM 806573. This <br /> eccumulation of grease inside the plenum and duct. appliance nozzle accounts for one flow number, and the tip is <br /> Organic coaking grease, either animal or vegetable in nature, stamped with PM 264377. <br /> ' is a highly tlammable subslance wilh an unusual characteristic. The duct cross seclion can be any shape (i.e., round, squere, <br /> �� II heated sufli�ienlly, it will tlash into ilame betore it boils. In en• or rectangular)and Ihe duct itself can be of unlimited length. In <br /> i gineering tertns,orgenic cooking oil has an auto•ignition temper- accordance with NFPA 96, the exhaust lan should be lett run• <br /> • ature lower than its boiling point.This auto•ignilion temperature ning al Ihe time ol system discharge. A damper, il present, <br /> ranges between 600°F - 700°F, well within the temperature should be lett open at system discharge.However,it the damper <br /> range o1 many common cooking appliances and typical ignition �s closed,the system designer must insure that the duct nozzle <br /> sour.�s. Once the grease auto•ignites, rapid temperature rise discharge is not impeded by the closed damper. <br /> occurs. Typically, grease•lined duct fires may reach 2000'F or <br /> � more. Hoods and ducts are usually inaccessible to normal fire The nozzle requirements lor ducl prolection are as tollows: <br /> fighting methods such as poAab�e extinguishers or small hose �, pucl Perimeter 0 to 27 Inches <br /> �� streams. Fires of this inlensity represent significant exposure pne appliance nozzle.PIN 806573,is reqwred lor prolection <br /> problems to the building's structural elemenls. of a duct with a perimeter up to 27 mches. Reler to Figure <br /> In addition lo the hood and duct,somo ol the cooking appliances 281T)� <br /> represent lire hazards as well. p, p�ct Perimeter Be�ween 27 and 75 Inches <br /> In general, any appliance which produces grease vapors while pne duct nozzle, P/N 806572. is required lor proteclion ot a <br /> � operating is a potential fire hazard. Grease-producing appli� duct with parimeter grealer than 27 inches and less than or <br /> ances can be broken down into three general categories —grid- equal l0 75 inches. The ducl nozzle can also be used loi <br /> dles,IryerS,and broilers.The term"griddles"is meanl to include dur�s with perimeters less than 27 inches. Re1er to Figure <br /> Ilat griddles as well as griddles with grooves. Multiple burner p8�b). <br /> and hol-top ranges are included in this category. This type ot <br /> appliance represents a coated surface — a hot metal surface 3. Dur.t Perimeter Between 75 and 150 Inches <br /> ' coated with grease, with no liquid in dePfeci b eedepth so that ol ducts with pelreimePe s greate?�han 75 mchesiand less than <br /> a liquid surlace -- 1he liquid fuel has app or equal l0 150 inches. Refer to Figure 29 for nozzle place� <br /> food can be completely immersed in the lat. Deep•fat Iryers, <br /> pressure Iryers, broaslers,Woks, braising pans, and tilting skil- men1. <br /> �. lets are representative appliances included in this category. II one nozzle is used to protecl a ducl, it is located al Ihe <br /> "Broilers" represent a three•dimensional fire hazard, since Ihe geometric center ol the cross•sectional area Ihat it is protecting. <br /> meat or fish being broiled is placed on a grate sudace positioned and is located in the duct within 6 inches o1 Ihe plenum and <br /> �i usually above heating elemenls and a drip pan. Appliances in ductwork intertace. 11 two dud nozzles are used, they are <br /> � this category include upright broilers. eledric- and gas-radiant positioned as shown in Figure 29 and are also localed in the <br /> � broilers, lavarock and ceramic synthetic broilers, salamander duct within 6 inches ol the plenum/duct interface. <br /> � <br /> � <br /> I <br /> I <br /> 37 <br /> I U.L EX3559 <br /> �I May.1991 <br />