My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5927 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
5927
>
5927 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2017 3:56:13 PM
Creation date
2/25/2017 1:50:47 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
5927
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 16, 1997 <br />PL/BL/C �'/O«K5" <br />Lyons Construction <br />8217 Wade Road <br />Arlington, WA 98223 <br />Subject: Owner: <br />Job Address: <br />Plan Check Nu. <br />Dear Mr. Lyons: <br />Rag <br />5927 Oakes Avenue <br />55061 <br />In response to your applicatio�.i for a construcdon permit, your plans have been examined and you <br />are advised that the issuance of a permit is being withheld for the reasons listed below. These <br />comments address building issues only, additional revisions or additions may be required by other <br />departments (such as Utilities, Plamm�g or Fire). All references refer to the 1994 Umform <br />Build�ng Code, as amended by the State of Washington and/or Washington State Energy Code <br />1995 Edition, urdess stated otherwise. <br />In order for the processing of your application to continue, it will be necessary to <br />provide tha Building Div�sion with fwo copies of revisions reflecting necessary <br />corrections. <br />2. <br />4. <br />The plans as submitted do no[ meet the prescriptive requirements for lateral bracing. <br />Spacing of braceci wall lines shall not exceed 34 feet (10,363mm) on center in both the <br />longitudmal and transverse directions in each story. The addition ndiculaz�ro> the <br />(1219mm) walls (one on the back wall and one on the front wall), perpe <br />overhead door, with a 15"x7" spread footing with two (2) i/4 rebar would meet the <br />requirement (2326.4.1 UBC). <br />The 4x14 beam called out on the plans fails in section modulus, provide new beam <br />size,species and grade. <br />Provide minimum 36" (914mm) landing not more than S" (203mm) below the finished <br />floor at all entrance/exits (personnel door). <br />All braced wall panels shall be clearly mazked on plans (2326.11.3). <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure that <br />the proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />,%y� '/ �� <br />Jeff Heilman <br />Development Technician <br />m:;wy�1�.m�.�t.in <br />CITY OF EVERETT• 3200 Cedar Street � Everett, WA 98201 •(206) 257-8800 • Fax (206) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.