My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4945 OCEAN AVE 2018-01-02 MF Import
>
Address Records
>
OCEAN AVE
>
4945
>
4945 OCEAN AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 3:52:14 PM
Creation date
2/25/2017 2:13:41 AM
Metadata
Fields
Template:
Address Document
Street Name
OCEAN AVE
Street Number
4945
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEOTECHNICAL ENGINEERING STUDY <br />Mr. Rick Remsing <br />May 5, 2003 <br />E-10558 <br />Page 7 <br />Horizontal loads can be resisted by friction between the base of the foundation and the <br />supporting soil and by passive soil pressure acting on the face of the buried portion of the <br />foundation. For the latter, the foundation must be poured "neat" against the competent <br />native soils or backfilled with structural fill. For frictional capacity, a coefficient of 0.35 <br />can be used. For passive earth pressure, the available resistance can be computed using <br />an equivalent fluid pressure of three hundred fifty (350) pounds per cubic foot (pcf). The <br />passive pressure should be neglected on the downslope side of the residence. These <br />lateral resistance values are allowable values, a factor -of -safety of 1.5 has been included. <br />As movement of the foundation element is required to mobilize full passive resistance, the <br />passive resistance should be neglected if such movement is not acceptable. <br />Footing excavations should be observed by a representative of ECI, prior to placing forms <br />or rebar, to verify that conditions are as anticipated in this report. <br />Retaining and Foundation Walls <br />Retaining walls and foundation walls that act as retaining walls should be designed to <br />resist lateral earth pressures imposed by the retained soils. Walls that are designed to <br />yield can be designed to resist the lateral earth pressures imposed by an equivalent fluid <br />with a unit weight of thirty-five (35) pcf. If walls are to be restrained at the top from free <br />movement, the equivalent fluid weight should be increased to fifty (50) pcf. These <br />values are based on horizontal backfill and that surcharges due to backfill slopes, <br />hydrostatic pressures, traffic, structural loads or other surcharge loads will not act on the <br />wall. If such surcharges are to apply, they should be added to the above design lateral <br />pressure. The passive pressure and friction coefficients previously provided in the <br />Foundations section are applicable to retaining walls. <br />If design against earthquake loading is desired, a rectangular pressure distribution equal to <br />six times the wall height (6H) should be added to the above lateral earth pressure values. <br />In order to reduce the potential for hydrostatic forces building up behind the walls, <br />retaining walls should be backfilled with a suitable free -draining material extending at <br />least eighteen (18) inches behind the wall. The remainder of the backfill should consist of <br />structural fill. The free -draining backfill should conform to the WSDOT specification for <br />gravel backfill for walls (WSDOT 9-03.12(2)). A perforated drainpipe should be placed at <br />the base of the wall and should be surrounded by a minimum of one cubic foot per lineal <br />foot with three -eighths inch pea gravel. <br />Earth Consultants, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.