Laserfiche WebLink
~Pacif�Rarners=lnsutation-" <br />Air Leakage Blower Doorj Testing Certificate <br />House Address or Lot M.4�- e-) L YM of tr �'—'V �Y _ <br />a ower,Dgorloca ian.___.. <br />Ring: Open O J�VO 20 30 <br />d <br />Wind Speed: — mph Humidity: <br />Temperatum - S _° F Weather Condition: r5 cIiit n y <br />Formula: (CFM X 0.0551 / (CF/� X 144) 6,seline: <br />Calculations: — <br />�Szo x <br />Standard — Tested CFMso Test ReSlllt (SLA) <br />---- — — <br />0.00030 SLA - — <br />;lossary — <br />.FA: Conditioned floor Arca <br />:FMso: cubit Fcot pet Minute of air leakage at 50 pascals of pressure <br />'a scat (PA): The SI unit of pressure (equivalent to one newton per square meter) <br />d.A: specific leakage Area <br />.__ — . <br />Vasungton tatallncrgyCodo-re Retenecr--- -.- _-- --- --- - __--_ <br />02.4.5 Building Air Leakage Testing: All new construct ton and additions over 750 sq. ft. need to have a blower door test done and the <br />asulttng au leakage should be less than 0.00030 Specific Leakage Area (SLA) when tested at 50 pascals (0.2 inch w.c.) of depressurization. Testing <br />an be done any time after rough in and aftet installation of penetrations of the building envelope, including penetrations for utilities, plumbing, <br />Iecirical, ventilation and combustion appliances (and sealing of these penetrations) have been completed. Building officials can request that the <br />?st be conducrcd while building department staff is present. The blower door test results need to be recorded on the certificate that is requited in <br />action 105.4 <br />xemptions: <br />Additions less than 750 square feel <br />Once visual tuspertion has confirmed the presence of a gasket (see section 5o2.4), operable windows and doors manufactured by small F.usinr•.•. <br />tail be permitted to be scaled off at the frame prior to the test. 511ccifit I eakage Area (SLA) shall be aticulaled as follows <br />A rIUMSO x0.055)/(CFAx 344) <br />'here: <br />'(Aso = Slower door fan flow at 50 pascal pressure difference <br />;A = Conditioned Floor Area of the housing unit, convened to square inches <br />ping Testing: - - <br />Ienor windows a. -•I doors, fireplace and ::lave doors shall he closed but 1101 sealed. <br />rmpers shall be closed, but not sealer!; including exhaust. Intake, makeup all, back dralt• and the flue damprrs; interior (fools connecling <br />nditioned spaces shall be open; arcess hatches to conditioned cra:•zl spaces and conditioned attics shall be opened; moors connecting to <br />conditioned spares shall be closed but not sealed E[lErnr ,per sg for ! 0nimuous oiler wilco ventilation.ystem and heat reco-gee; vrntilatnrs <br />0 be dc: :f ;I"J sealed <br />_r-i lriY lt•]i ill:: Se dtl'1'A!:-, ^s:gtlr; ,pit BCC!Irol rl.i <br />i� �,�i�:.. �. L-.i r{ �;I•t � � L•'�-Lint; In.7 it �: ill <br />