Laserfiche WebLink
. � � <br /> Ltr. C. Dudlcy (B0403-045) <br /> April 12, 2004 <br /> Page 2 <br /> 8. Show insulation baffle in attic. Baffle ro extend G' vertically above batts and I2" <br /> vertically abovc loosc fill insulation. <br /> 9. Anchor bolts to be spaced at not morc than 48" o.c. specify 7" minimum 2 anchor bolts <br /> per picce and within 12" or each end of each piece. Provide 2" x 2" x 3/l6" plate <br /> washcr on all anchor bolts. <br /> 10. Specify minimum G" wood to earth dearance. (Concrete supporting a wood swcture is <br /> required to project a minimum of 6" above the finished grade.) <br /> f I. Providc solid blocking at rafters capable of trans(erring roof loads into exterior walls. <br /> 12. Pantry rcyuires R-38 in the cciling, R-21 in the walls and R-30 in the floor. Please <br /> change framing membcr sizc to reflect thcse requirements. <br /> 13. Show how attic in addition is ventilated. <br /> Plcase prcpan: a resronse Ictter showing where cach item in this correction Ietter is addressed on <br /> thc plan sct. <br /> Upon resubmittal of the drawings, your applicalion will he given prionty and plan review will <br /> rccommence. <br /> All rcyuired submittals shall bc of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in complianee with all adorted codes. <br /> Sinrcrcly. <br /> Jcff Hcihnan <br /> Dcvclupmcnt Tcchnician <br /> ` , . <br /> _ , <br /> ui�:mn•ie�c��isra�u,n�t.nvmn+m.�us ir+au oi.�amic uxi `�. <br />