Laserfiche WebLink
( � <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#601. <br /> 5. Connect side sewer per City Standard#'s 601, G02, 604. <br /> G. Connect all roo(top downspouts to ihe side sewer. <br /> 7. Connect rooftop downspouts to the drainage system provided for this lot. <br /> B. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everelt Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2' �zep and 25' long. See attachment for <br /> more d�tails. <br /> / 9. 1 The conlractor must meet with lhe Public Works Inspector to discuss potential drainage routing prior to <br /> �� beginning the project. <br /> 10. Install erosion control measures as determined by the Public Works inspector, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> 11. Install erosion control measures per City of Everelt Standards for small parcels <br /> 12. Remove erosion control measures upon completion of the project prior to final approval of the permit. <br /> 13. J All excavated material from foundation, sidewalk and driveways shall be hauled to an approved, <br /> permitted site. No wasting of material is allowed on this building lol. <br /> 14. � No dirt, mud, rocks or debris to be tracked onto roadway. <br /> 15. No building malerials to be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian lravel. <br /> 16. Adjusl water meter box 1"above sidewalk grade. <br /> 17. Remove and repiace curb, c�utler and sidewalk as per Cily of Everett Standard Plan#'s 305A 8 306 on <br /> this proposal's frontage as directed by�F�e Public Works Inspector(i.e. ail unused driveways �nd any <br /> broken or damac�ed area must be repl_..ed). <br /> 18. Install a Type I concrele driveway per Cily of Everett Standard#307. <br /> 19. Pave driveway from lhe (ront property line out lo the street paving. <br /> 20. Contact lhe Water District for connectin�7 provisions for lhis building's water and <br /> sewer services. <br /> 21. A calch basin as per City Standard Plan�402 wilh a gas trap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is lo be installed, llie pressure line must discharge into a private manhole, then <br /> gravity flow across ihe public righl-of-way. <br /> 23. A sprinkler system is required for this building in compliance with the requiremenls of NFDA Standards <br /> 13D. <br /> �WCommenls <br /> � . , J <br />