My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1325 PACIFIC AVE 2016-01-01 MF Import
>
Address Records
>
PACIFIC AVE
>
1325
>
1325 PACIFIC AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2017 5:41:10 AM
Creation date
2/25/2017 5:40:59 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
1325
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
< < <br /> Puecrc woR�rs <br /> December 5, 2011 <br /> Ron Auld <br /> Rauld@synergyconstruction.com <br /> RE: Owner: Potala Vi�lage LLC <br /> Job Address: 1325 Pacific Ave <br /> Plan Check No: Blili-024 <br /> Dear Mr Auld; <br /> In response to your applicadon for a construction permit, your plans have been examined and <br /> you are advised that tfie issuance of a permit is being withheld for the reasons listed below. All <br /> references refer to the 2009 Intematlonal Building Code, as amended by the State of <br /> Washington and adopted by the City of Everett and the Washington State Energy Code, 2009 <br /> Edition, unless stated atherwise. <br /> In order for the pn�oessing of rour applkation Lo aontlnue, it wlll be neoessarlr to <br /> provide the Bufldinp Division witfi two oomplete new sets of aonstrudfon <br /> documents reHecting tfie oort+ections requcsbed. <br /> 1. There appear to be a number issues with the proposed Type 1 hood and exhaust duct <br /> as submitted. The City of Everett lypically requires a separate mecheniwl pertnit for <br /> Type 1 hoods. At tfie time all of the issues will need W be resn�ved. Please be advised <br /> tfiat there should be communication between the kitchen layout desigr.er and the hood <br /> and duct installer/s to try to avoid field construction issues. <br /> 2. The plans should provide the requirements for door panic hardware in accordance with <br /> IBC 1008.1.10. <br /> 3. The plans should provide all information to assure compliance with door swing and door <br /> latch requirements of IBC 1008.1.2 and 1008.1.9.3 respectively. <br /> If you have any questions, please call me at 425-257-7264. <br /> Upon resubmittal of the drewings, your applicadon will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of su�cient detail and contain suffident infnrtnation to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely,V/ 1 " � Q ,, <br /> ✓l/� <br /> Steve Miller <br /> Associate Engineer <br /> s:/tnthy/�lBll]1-0M p775 Catlllc Me) <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br />
The URL can be used to link to this page
Your browser does not support the video tag.