My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1818 PACIFIC AVE BASE FILE 2018-01-01 MF Import
>
Address Records
>
PACIFIC AVE
>
1818
>
BASE FILE
>
1818 PACIFIC AVE BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2018 2:07:09 PM
Creation date
2/25/2017 6:14:29 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
1818
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
401
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- _ � �-, <br /> PC k49450 <br /> October 25, 1995 <br /> Page 3 <br /> �2. An 8'-6� floor to floor height is indicated for the basement parldng ga�age. Please <br /> provide clear, detailed drawings to ensure 7'-0" minimum headroom within garage. <br /> Include sprinkler piping, heads and hangers, waste piping, beams and any other <br /> potential obstructions. (During conswction will not be the time to discover a problem. <br /> As we have had a great deal of trouble on past projects with this requirement we will <br /> not be very understanding). Sec. 311.2.3.3. <br /> � 13. A 17" min. deep knee space is required at accessible sinks. Sec. 1106.11.7.3.1 Re: <br /> Defail 2 sheet A 13. <br /> ,/14. Please provide enlarged stair plans for all levels of each stair. IDustratc handrails, <br /> eztensions, signage, etc. <br /> ✓15. Please call out wall rype on floor plans. <br /> �16. Most of the units have a 4' deep foyer. 60" min. is required by Sec. 1106.10.3. <br /> ✓17. Please provide detailed dimensions for walls within units. <br /> �� <br /> �(/� 18. Please indicate exhaust fans (including cfm rating) and outdoor air inlet system per <br /> VIAQ Code. Please also indicate and detail any shafts that may be required for these <br /> systems. <br /> ✓19. Please review the attached combustible piping policy sheet. <br /> ✓20. Units C & O bathroom doors must provide a 32^ min. clear opening. <br /> ✓21. May units have re-lites to the main corridor (E & F for ezample). The area of these <br /> re-lites cannot ezceed 25% of the uea of the common unidcorridor wall. Sec. <br /> 1005.8.2. <br /> ✓ 22. Many of the enlazged pians are not oriented the same as the iypical floor plan. Please <br /> revise. (See also item 10). <br /> � 23. The eating bar in ani�K nust be accessible per Sec. 1106.19. <br /> i/24. Please detail (or specify) any door thresholds (s��ecifically deck doors) that are required <br /> to be acce�sible. <br />
The URL can be used to link to this page
Your browser does not support the video tag.