My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE 1ST FLOOR 2018-01-01 MF Import
>
Address Records
>
PACIFIC AVE
>
916
>
1ST FLOOR
>
916 PACIFIC AVE 1ST FLOOR 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2019 12:17:36 PM
Creation date
2/25/2017 8:30:27 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
1ST FLOOR
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
764
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . <br /> Mr. Tim Tyler <br /> Page 2 <br /> June 19, 1991 <br /> 2. �istinq Corridors and A.quir•a azits <br /> A. Please see the attached floor plans that have been colored <br /> to indicate one-hour smoke, one-hour, two-fiour, and four- <br /> hour seperations. If these plans are acceptable, please <br /> return them to our office so we may incorporate them into <br /> the conetruction documents. <br /> The one-hour smoke aeparations have been indicated vith <br /> the color purple. The areas within each emoke compartment <br /> and adjacent emoke compartwent are as follows: <br /> tiain Floor Emerqency Department 13,023 sf <br /> !lain Floor Adjacent Compartment 17,760 sf <br /> First Floor Surqery Department 18,942 sf <br /> First Floor 1ldjacant �o�epartment 15,510 sf <br /> 1111 of the above square footaqes are within the allowable <br /> 22,500 square foot waxinum, according to UBC Section 1002 <br /> (b) . The maximum dimension is the east-west dimension of <br /> Surqery and is 150 feet. <br /> The requirement in Section 1002 (b) that requires each <br /> conpartment to have the capacity to hold the occnpanta of <br /> the adjacent compartw�ent ie intended to protect both <br /> ambulatory and nonambulatory patients for a sufficient <br /> amount of time to provide exitinq from that iloor and <br /> buildinq. The ebove adjacent aquare footaqes indicate <br /> more than an adequate capacity. To illustrate this, <br /> suppose that every bed in the Surgery Depertment is <br /> occupied includinq each operatinq room, even though this <br /> is functionally impossible. This Would total �6 non- <br /> ewbuletory patients at 30 square feet each and equals <br /> 1,080 equare feet. In addition, assume that iE there are <br /> two additional occupants for each nonambulatory patient et <br /> 6 square feet each, this equale 412 square feet. The <br /> total space tequired in the adjacent compartment would be <br /> 1,512 square feet. It also ehould be noted that the <br /> adjacent emoke cowpartwants to both Emergency and Surqery <br /> Departn�ents have direct exitinq to the exterior qrada as <br /> well as additionnl smoke compartments within the 8outh <br /> Ninq. The doors defininq swoke con�partments will be <br /> tiqht-fit;:inq, swoke- and draft-control assemblies, and <br /> fire-protection reted to 20 minutes. When installed <br /> across a corridor, they shall be double egress without <br /> center mullion and shall e�eet all additional requirements <br /> of Section 1002 (b) . <br /> B. The one-hour corridors have been indicated vith the color <br /> red, in the previous meetings, we requested that you <br />
The URL can be used to link to this page
Your browser does not support the video tag.