Laserfiche WebLink
( <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard #601. <br /> � <br /> �5. Connect side sewer per City Standard #'s 601, 602, 604. <br /> �, Connect all rooftop downspouts to the side sewer. <br /> 7. Connect rooftop downspouts to the drainage system pruvided for this lot. <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everett Storm <br /> Manual 3-2.G.2. 7he approximate size trench is 3.5'wide, 2'deep and 25'Iong. See attachment for <br /> more details. <br /> �_9�. The contractor must meel with the Public Works Inspector to discuss polenliai drainage routing prior to <br /> beginning the project. <br /> 10. Install erosion control measures as determined by the Public Works inspector, such as silt fence, straw <br /> bales, swales,or erosion blankets. <br /> -� <br /> `1 t. Inslall erosion control measures per Cily of Everett Standards tor small parcels <br /> �"` <br /> �2:' Remove erosion control measures upon completion of lhe projecl prior lo final approval of the permil. <br /> (13� All excavaled malerial from found�tion, sidewalk and driveways shall be hauled lo an approved, <br /> permitted site. No wasting of material is allowed on this building lot. <br /> � <br /> �14:' No dirt, mud, rocks or debris to be tracked onto roadway. <br /> 15 ' No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian travel. <br /> � <br /> �6. Adjust water meter box 1"above sidewalk grade. <br /> 17. Remove and replace curb, gutter and sidewalk as per Ciry of Everett Standard Plan #'s 305A& 306 on <br /> this proposal's(rontage as directed by lhe Public Works Inspeclor(i.e. all unused driveways and any <br /> broken or damac�ed area must be replaced). <br /> 18. Install a Type I concrele driveway per City of Everett Slandard #307. <br /> 19. Pave driveway from the fronl property line out to the slreet paving. <br /> 20. Contact the Water Districl for connecting provisions for this building's water and <br /> sewer services. <br /> � <br /> �21. A catch basin as per City Standard Plan#402 with a gas trap per Standard Plan #410 is required for the <br /> ` parking area. <br /> 22. IF a sewer pump system is to be ins�alled, the pressure line musl discharge into a private manhole, then <br /> c�ravity flow across the public righl-of-way. <br /> 23. A sprinkler system is required for this building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> PiYCommenls <br /> L/ <br /> � <br />