Laserfiche WebLink
L , R / / <br /> t ` ' <br /> 11. Provide tempered glass in hazardous locations per sect. 2406 UBC. <br /> 12. Show calculations for attic ventilation specify siu(s) and location(s) of vents. <br /> 13. Site plan may need to be updated with alt of the sacne information that was on the <br /> previously appmved plan. <br /> 14. Verify light and ventilation requirements are met in proposed living room. <br /> 15. Specify 1 3/8" solid core wood door with self closer or 20-mim►te rated door at <br /> garage/dining room. <br /> 16. Show how Energy Code requirements are met. <br /> 17. Anchor bolts shall be spacai at not moa than 48" o.c. and within 12" of each end <br /> of each piece. 2" x 2" x 3/16" plate washer on all anchor bolts. <br /> 18. Specify how ledger is attached to existing house, (at master bedroom addition). <br /> 19. Provide floor or landing on each side of all entrance/exit doors. Landing shall bc <br /> not more than 8" below the finished floor. <br /> Please pravide a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmital of the drawir.gs, your application will be given priority and plan review <br /> will commence. <br /> All required submittals shall be of sufficient detail and contain sufficient informltion to <br /> ensure that the proposed structure will be consuvcted in compliance with all adopud <br /> codes. <br /> Sincerely, ' � <br /> �--. Z ��y� <br /> leff He' an � <br /> Devel pment 1'xhnician <br /> JH:jr.C(q09-026 <br />