My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10120 MERIDIAN AVE 2016-01-01 MF Import
>
Address Records
>
MERIDIAN AVE
>
10120
>
10120 MERIDIAN AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2017 7:42:39 PM
Creation date
2/25/2017 7:42:25 PM
Metadata
Fields
Template:
Address Document
Street Name
MERIDIAN AVE
Street Number
10120
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/�lBL/C N/O.l7Kri C � <br /> December 20, 2000 <br /> Chong Kyu Yi <br /> 10120 bieridian <br /> Everett WA 98208 <br /> Subject: Own�r: Yi <br /> Address: 10120 Meridian <br /> Plan Check#: C0012-005 <br /> Deaz Mr. Yi: <br /> In response to your application for a construction permit, your plans have been examined <br /> and you are advised that the issuance of a permit is being withheid for the reasons listed <br /> below. T'hese comments address building issues only. Other departments (such as <br /> Utilities, Planning or Fire) may require additional revisions or additions. All references <br /> refer to the 1997 Unifortn Building Code, as amended by the State of Washington and/or <br /> Washington State Energy Code 1997 Edition, unless stated othenvise. <br /> In order for the processing of your application to continue, it will be necessary to provide <br /> the Building Division with two complete new sets of drawings reflecting the corrections <br /> requested. <br /> �1� Unless roofs aze sloped to drain over roof edges, roof drains shall be installed at each <br /> low point of the roof. <br /> Roof drains shall be sized and dischazged in accordance with the Plumbing Code. <br /> �Where roof drains aze required, overflow drains having the same size as the roof <br /> drains shall be installed with the inlet tlo�v line located 2 inches above the low point <br /> of the roof, or overflow scuppers having three times the size of the roof drains and <br /> having a minimum opening height of 4 inches may be installed in the adjacent parapet <br /> walls with the inlet t]ow line located 2 inches above the low point of the adjacent <br /> roof. <br /> O�•ertlow drains shall discharge to an approved location and shall not be connected to <br /> roof drain lines. <br /> / 3./Provide smoke detecror centrally located in the corridor or area giving access to <br /> �� slecping rooms. <br /> CITY GF EVEFETT• 3200 Cedar Slreet • Everett. WA 98201 • (425) 257-8800 • Fax(425) 257-8856 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.