' ' �� ( °UBLIC WORKS PERMIT COMM TS <br /> 4. Connect side sewer per City Standard#601. <br /> /! 5/� Connect side sewer per City Standard#'s 601, F02,604. <br /> l�A/ <br /> 6. Connect all rooftop downspouts to the side sewer. <br /> (/ 7./ Connect rooflop downspouts to the drainage system provided for this lot. <br /> '�/ <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everett Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2'deep and 25'long. See attachment for <br /> more details. <br /> 9. The contractor must meet with the Public Works Inspector to discuss potential drainage routing prior to <br /> beginning the project. <br /> 10. Install erosion control measures as determined by the Public Works inspector, such as silt fence, sfraw <br /> bales, swales, or erosion blankets. <br /> � <br /> 11. Install erosion control measures per City of Everett Standards for small parcels <br /> 12. Remove erosion control measures upon completion of ihe project prior to final approval of the permit. <br /> 13. All excavated material from foundation, sidewalk and driveways shall be hauled to an approved, <br /> permilted site. No wasting of material is allowed on this Guilding lot. <br /> 14. No dirt, mud, rocks or debris to be tracked onto roadway. <br /> • 15. No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian travel. <br /> 16. Adjust water meter box 1"above sidewalk grade. <br /> 17. Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan#'s 305A&306 on <br /> this proposal's frontage as directed by the Public Works Inspector(i.e. all unused drive�vays and any <br /> broken or damaged area must be replaced). <br /> 18. Install a Type I concrete driveway per City of Everett Standard#307. � <br /> 19. Pave driveway from the front property line out to the street paving. <br /> 20. Contact Ihe Water District for ccnnecting provisions for this building's waler and <br /> sewer services. <br /> 21. A catch basin as per Cily Standard Plan#402 with a gas trap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be installed, the pressure line must discharge into a private manhole, then <br /> gravity flow across the public right-of-way. <br /> 23. A sprinkler system is required for this building in compliance with the requiroments of N�Standards <br /> 13D. <br /> FOR PUBLIC WORKS INSPECTION, CALL RANDY AT 425-339-7403/CLIFF Al"425-339-7404 <br /> PWComments �� <br /> �a� ; <br /> �,,_ <br />