Laserfiche WebLink
( <br /> Pr�jcct: Dombrovskiy <br /> Job Address: 10232 Meredian Avenue <br /> Plan Chech No: CO505-03R <br /> In response to your revisions of the project ihe next revisions �vere made. <br /> 1. Poundation plan shows 4x8 joists @ 24"o.c., "new in floor joisls details show 2!c10 and 2x8 <br /> plcasc clarify. Cross-rcference details to wherc Ihey occur on foundation and llour pluns. <br /> All joist arc 2x10. See foundation and Iloor plan sheets. <br /> '_'. Provide 3"x3"xl/4" plate washers on all anchor bolts in braced wall lincs. <br /> "1'hc rcvision was maid. Scc sheci 3 "Ploor plad'General notes #3. <br /> 3. Specify all braced wall lincs on plan view, per section RG03.10 IRC. <br /> "I'l�c necdcd inforn�ation is added. Sce shcet 3 "['loor plan-'. <br /> 4. Provide solid blocking betwecn,joist under bcaring walls mid braced wall lines whenjoists <br /> arc perpcndicular to braced wall lincs. Show on pluns. <br /> I he necJed infornialion is addcd. Scc shcet '_' ..Puundation nutes' #I and shcet i "Cicneral <br /> notes" #I. <br /> 5. Providc double joisls under p�irallcl bcaring partitions and braccJ wall lines. Sho�v on plans. <br /> The needed infonnation is added. See sheet 2 and Poundation notes#2. <br /> (i. Spccify all glazing to bc U-035 or Icss per Option l. Table G-1, Washinglon Stalc Gncrg�� <br /> Code. Skylight to be U-0.58 or less. <br /> "I'hc needed infomialion is added. Sec sl�eet I Gnergy Codc notes. <br /> 7. 1'rovide foundation vents within 3'-0" oCall corners. Show on plans. <br /> The revision was made. Sec sheet 2 '9�oundaliod' <br /> 8. Spccily requircm�nts of Washington Statc Ventilation and Indoor Air Quality Codc. <br /> I'he needcd infonnation is sdded. See shcet 1 Wholc housc ventilation notes. <br /> 9. Specify whole house ventilation systcm. Show on I'I;ms. <br /> 7�hc nccded infiirniatiun is added. Sce shcet 1 Whole housc vcntilation notes and shect 3. <br />