My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1930 MERRILL CREEK PKY INTRACORP 2018-01-01 MF Import
>
Address Records
>
MERRILL CREEK PKY
>
1930
>
INTRACORP
>
1930 MERRILL CREEK PKY INTRACORP 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2018 2:06:46 PM
Creation date
2/25/2017 9:57:40 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
1930
Tenant Name
INTRACORP
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� * <br /> PUBL/C /�YO�i�Kr <br /> ; <br /> � <br /> February 4, 1997 <br /> John Tacke <br /> Smith Fire Systems <br /> 1106 54th Avenue E <br /> Tacoma, WA 98424 <br /> Subject: Owner: Intracorp <br /> Job Address: 1930 Merrill Creek Parkway <br /> Plan Check No.: 54067 <br /> Dear Mr. Tacke: <br /> In response to your application for a conswction permit, your plans have been examined and you are i <br /> advised that the issuance of a permit is being withheld for the reasons listed below. All references � <br /> refer to the 1994 Uniform Building Code, as amended by ttie State of Washington and/or NFPA 13, � <br /> 1994, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to i <br /> provide the Building Div�sion with two copies of revisions reflecting necessary d <br /> corrections. <br /> 1. Provide structural calculations for the detail labeled "Hanger". Provide the dimensions of <br /> the "Tolco figure 58 side beam bracket". The nailer appears to be overstressed, <br /> perpendicular to grain, by the lag screw. Provide compliance with UBC Table 23-111-U. <br /> 2. Provide structural calculations for tlie detail labeled "Hanger Wl, W3" to show <br /> compiiance with NFPA 2-6.1. Are Hilti kwik-bolts required to be specially inspected per <br /> UBC 1701.5.3? Analyze bolts for combined shear and tension. ?rovide member sizes <br /> and weld information. <br /> 3. Provide member sizes and weld information for the detail labeled "Hanger W2". <br /> 4. Provide structural calculations for the detail labeled "Hanger W4, WS". (See Note 2 <br /> above.) <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure that the <br /> proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, � y�_ � /J Q <br /> //k,.l'f•-- <br /> Steve Miller, Pb <br /> Associate Engineer <br /> SM:jWMklqirk.l l <br /> CITY OF EVERETT• 3200 Cedar Street• Everett, WA 98201 • (206) 257-8800 • Fax (206) 257-8856 � <br />
The URL can be used to link to this page
Your browser does not support the video tag.