<br /> Prescriptive Spaces Occupancy: O Warehouses,storage areas or aircrafl storege hangers QOther
<br /> Qualification Checklist Lighting Fi:Wres: ❑ Check here if at least 95%of fixtums in the space meet all four cntena:
<br /> Nm� n occ�o��=y ryoo�s•om�r a�e ruwm
<br /> answer rs cnectotl,the numbar al Gamms�n 1.Fixtures are Ouorescent,nonJensed,with anly one or nvo lamps,and
<br /> t�e spazo Is nol limited by CoOo. Cbarty
<br /> ineicate Ine�e sparos an plans. II not 2.Lamps are T-1,T-2,T-0,T-5,T-6,T-E 3.Lamps ere 5-50 Watts,and
<br /> QualiGea,aa LPA CalcuWbons. 4.Ballasts are electmnic ballasls 5.Ezit lighls<5 watlsl6ztura
<br /> 6.Screw-in cornpacl lluorescent fiztures do nol qualify
<br /> 7ABLE 15•1 Unit Lighting Power Allowance LPA _
<br /> i�-�5C LPA Use LPA
<br /> � W/s Wls
<br /> �_Painling welding,ca eN ,machine sho s 2.3 Police and fire sla6cns ��5
<br /> [larbcr shoPs,bcaul sho s 2.0 Alna atnums ���
<br /> Hotel banQueVconferencelexhibilion ha�l ' 2�0 Assembly spaces.auditonums,gymnasia ,healers 7.0
<br /> Laboratones 7-.0 Gmu R-1 common areas 1.0
<br /> Aircralt rePair han ars 1.5 Pwcess Planls 1.0
<br /> Cafe�erias,last Icod eslabli5hmen(s i5 Restauranlslbars' ��0
<br /> Faclones,worksho s handlir. areas 1.5 Lockerandlorshower(acilities ��B
<br /> �as stations.aulo repair sho s 1.5 Warehouses� ,slorage areas 0.5
<br /> Institutions 1.5 Aircrafl stora e han ars 0.4
<br /> Libraries 1.5 RMail",retail banking ��5
<br /> Nursing homes antl hotellmotcl guest rooms 1.5 Parking garages See Sectlon
<br /> 1532
<br /> W holesale slorcs allet rack shelvin 1.b
<br /> Mall concourses 1.4 Plans Suhmitted tor Common Areas Onl
<br /> Schools huildings(Group E occupancy only), 7.35 M11ain floor building lobbies (e:cept mall 12
<br /> school classrooms,da care cenlers concourses
<br /> Laundries 1.3 Common areas,wmdors,loilet facilities and 0.8
<br /> washrooms,elevator lobbics
<br /> Olfice buildings,oifice/odminislralive ereas in 1.2
<br /> tacilities of other use�ypes(including bul not limited
<br /> to schoolss�ospitals,inslilutions,museums,banks,
<br /> churches)' ' ---
<br /> Foolno(es tor Table 15•t
<br /> 1) In cases in which a general use and a specific use are listed,lhe specific use shall apply.In cases in which a use is nol
<br /> mentioned speciGcally,the lJnit Power Allowance shall be determined by the building of6cial.This de�ertnina6on shall be based
<br /> upon Ihe mosl compareble use specifed in lhe lable See Section 1512 for exempt areas.
<br /> 2) The watls per square fool may be increased,6y hvo percenl per fool of ceiling heighl above twenty feel,unless spec�fically
<br /> directed olhenvise by subsequenl foolnotes.
<br /> 3) Watts per square foal of mom may be increased by two percent per fool of ceiling height above twelve feet.
<br /> 4) For all olher spaces,such ns seating and common areas,use the Unit Light Power Allowance for ossembly.
<br /> 5) Watis per square foot of room mny 6e increased by hvo percenl per foot of ceiling height a6ove nine feet.
<br /> 6) Includes pump area undzr canopy.
<br /> 7) In cases in which a lighting plan is submitled for only a poAion of a Ooor,a Uni1 Lighling Power Allowance of 7.35 may Co wed
<br /> lor usable olfice Ooor area and 0.00 walts per square(oot shail be used for the common areas,which mny include elevator
<br /> space,lobby area and resl rooms.Common areas,es herein defned do not include mall concourses.
<br /> 6) For Ihe fue eng�nc room,the Unit Li�hting Power Allowance is 1.0 watts per square fool.
<br /> 9) For indoor sport lournament couds with adjacent speclalor sealing,the Unil Lighling Power Allowance for lhe court erea is 2.6
<br /> walls per squarc(ool.
<br /> 70) Uisplay window illumination installed wilhin 2 feet of lhe window,lighting for Iree-slanding display where Ihe Iighling moves��ith
<br /> the display,end building showwse illuminalion wliere the lighting is enclosetl wilhin Ihe showcase are exempt.
<br /> An addilional 1.5 wlft'of inerchandise display luminaires are ezempl pmvided thal they comply with all three of lhe following�.
<br /> a) located on ceiling-mounted lrack or direclly on or recessed into the ceiling itseB(nol on Ihe wall).
<br /> b) adjus�able in bolh lhe honzonlal and vedical azes(vertiwl a:is only is acceptable lor Iluorescenl and olher fizWres wdh
<br /> two points o(Irack altachmenl).
<br /> c) ftled with Wngslen halogen,fluorescen�,or high intensily dischorge lamps.
<br /> This additional lighting power is allowed only if lhe IigMing is acWally installed.
<br /> 11) Provided lhat a floor plan,indicating rack location and heighl.is submitled,the square footage for a warehouse may be
<br /> defined,for compuling the intedor Unit Lighting Power AlloNance,as Ihe floor area not covered by racks plus lhe vertical face
<br /> area(access side only)ol the racks.The height allowance defined in footnote 2 applies only lo lhe Ooor area nol covered by