7/26/99 1 :49 :4 pm Shareware Release page 11 <br /> Seaway Center <br /> Storm Drainage Conveyance Calculation <br /> � 7144-con <br /> ----------------------------------------------------- <br /> REACH SUMMARY i <br /> PIPE REACH ID No. POS <br /> From: To: <br /> Pipe Diameter: 0.6667 ft n: 0 . 0120 � <br /> Pipe Length . 4U .0000 ft s: 0 .0038 <br /> Up invert : 601. 0000 ft down invert : 600 . 8500 ft <br /> Collection Area: 0 .1100 Ac. <br /> Deaign Flow . 0. 0610 cfs Dsgn Depth: 0 . 12 ft <br /> Pipe Capacity . 0 . 8647 cfs <br /> Design Vel . 1.3579 fps Travel Time : 0.49 mir, <br /> Pipe Full Vel . 2 .5422 fps <br /> PIPE REACH ID No. P06 <br /> From: To: <br /> Pipe Diameter: 0 .6667 ft n: 0. 0120 <br /> Pipe Length . 92 . 0000 ft s : 0 . 0038 <br /> Up invert : 600 . 8500 ft down invert: 600 .5004 ft <br /> Collection Area: 0 . 1900 Ac. <br /> Design Flow . 0 . 1054 cfa Dsgn Depth: 0.16 ft <br /> Pipe Capacity . 0 .8704 cfs <br /> Deaign Vel . 1.6005 fps Travel Time: 0 . 96 min <br /> Pipe Full Vel . 2 .5591 fps <br /> PIPE REACH SD No. P07 ' <br /> From: To: <br /> Pipe Diameter: 0 .6667 ft n: 0 .0120 <br /> Pipe Length . 86 . 0000 ft s: 0 . 0058 <br /> Up invert : 601 . 0000 ft down invert : 600 . 5003 ft <br /> Collection Area: 0 . 1100 Ac. <br /> Design Flow . 0 . 0610 cfs Dsgn Depth: 0 .11 ft <br /> Pipe Capacity . 1. 0763 cfs <br /> Design Vel . 1. 5835 fps Travel Time: 0 . 91 min <br /> Pipe Full Vel . 3 .1643 fps <br /> PIPE REACH ID No. P08 <br /> From: To: <br /> Pipe Diameter: 1 .0000 ft n: 0 . 0120 <br /> Pipe Length . 87 . 0000 ft s : 0 . 0023 ' <br /> Up invert : 600 . 5000 ft down invert : 600 . 2999 ft <br /> Collection Area: 0 .4500 Ac. I <br /> Design Flow . 0 . 2495 cfs Dsgn Depth: 0 .25 ft <br /> Pipe Capacity . 1 . 9965 cfs I <br /> . Design Vel . 1 . 6468 fps Travel Time : 0 . 88 min ; <br /> < Pipe Full Vel . 2 . 6089 fps <br />