My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3427 NASSAU ST 2018-01-02 MF Import
>
Address Records
>
NASSAU ST
>
3427
>
3427 NASSAU ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 10:14:27 AM
Creation date
2/26/2017 1:51:40 AM
Metadata
Fields
Template:
Address Document
Street Name
NASSAU ST
Street Number
3427
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONPUANCE <br />REQUIRED <br />INSPECTION I IMPORTANT: Disregard topics that don't describe your building or equlpmem. DO NOT <br />APPROVED place checks In the two left columns. <br />p 0 ® Alrflow from habitable rooms to whole -house fan ensured by undercut doors or grills (VIAQ, S. 302.6.4) <br />O E3 ©r Loosetlll Insulation OK H (S.502.1.4.5): <br />cimaximum ceiling slope L3 in 12 <br />pr. 30" of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />0 0 Q6 Rill black polyethylene ground cover, lapped 12- at Joints and to foundation wall <br />0 0 ©i C <br />wlA <br />learances shall meet listed minimums between Insulation and (S.502.1.4.3): <br />0 chimney ❑ Non -IC rated recessed lights: 1/2" to combustables, 3'to insulation. <br />0 0 tlic hatch shall be insulated to required ceiling R-value and Is weatherstripped (S.502.1.4.4) <br />O 0 ?- Attic access shall have wood dam or equivalent to retain loose fill insulation in attic (S. 502.1.4.4) <br />0 O 11 exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />0 d Service hot & cold water piping shall be Insulated to R-3 (S. 503.11) <br />O O Service recirculation hot water piping shall be Insulated to Table 5-12 levels. <br />0 0 hemostat provided for each HVAC system with range of 55-75' R(heating) (S.503.8.1.1). <br />0 0 R <br />r <br />a <br />s <br />eadily accessible, automatic or Manual means provided to restrict or shut-off Heating Input to each <br />zone or floor during periods not requiring heat (S. 503.8.3.1). <br />0 0 Controls for backup heat prohibit simillaneous operation of the primary system (S. 503.2.2(3)). <br />0 0 a Mechanical ventilation systems shall have proper timers, and/or switches (S. 302.3). <br />O 0 Mechanical ventilation ducts shall have insulation z R-4 in unconditioned spaces (VIAQ, S. 302.5) <br />0 0 Mechanical supply ducts III conditioned spaces shall have x R-4 insulation (VIAQ, S. 302.5) <br />0 0 upply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />0 p Supply and return air ducts shall have sealed duct joints in unconditioned spaces (S. 503.10.2). <br />0 0 HVAC plenums, supply, and return air ducts shall have R-8 insulation (Table 5-11. All options) <br />00 Electric water heater(s) shall have (S. 504.2.1, 504.3, 504.4) : <br />❑ separate power .. shut-off E3 1987 NAECA Lable on tank <br />❑ noncompressible R10 pad (unhealed spaces only) o Temperature settings 120 F. <br />p 0 s Showers and lavatorlea shall limit flow to s 3.0 gallons/minute (S. 504.8.1). <br />E3 0 Swimming pool(s) (S. 504.5) shall have: <br />0 readily accessible ONIOFF switch (pump, heater) E3Pool cover ❑ Piping Insulated to S. 503.11 <br />0 p r Flreplace(s) (VIAQ, S. 402.3) shall have: <br />0 6 square Inch combustion air supplyducl w/ operable damper, directly connected to the fire box <br />o Tight filling glass or metal doors; or flue draft Induction fan. 0 Tight fitting flue damper. <br />0 0 Solid fuel burning appliances) (VIAQ, S. 402.2) shall have: <br />0 Tight fitting glass or metal doors <br />0 Outside combustion air source directly connected to the fire box <br />0 Exception: Non -direct, 4' diameter, dampered, combustion air source: allowed only for (1) new stove <br />installations In existing homes where obstructions preclude direct combustion air, or (2) Central <br />healing systems located in unheated spaces. <br />C3 O Three month, etched track, radon monitor, printed Instructions, and an information sheet shall be <br />supplied by the builder to each single family dwelling and to each ground floor unit of mufti -family dwellings <br />(VIAQ, S. 502.2.1). <br />WSEC Final phase requirements: <br />Inspected by Date <br />Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.