My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 NORTH PARK DR 2016-01-01 MF Import
>
Address Records
>
NORTH PARK DR
>
1010
>
1010 NORTH PARK DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2017 3:39:13 PM
Creation date
2/26/2017 2:08:15 AM
Metadata
Fields
Template:
Address Document
Street Name
NORTH PARK DR
Street Number
1010
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Churehill Residcnce 1-1501 <br />1010 North Park Drive April 10.'_OU3 <br />C•verett, �Vashington P��S- � <br />weiehts, are based on the assump[ion of a uniform level backfill �vith no uuildup of hydrostatic <br />pressure bchind ttte walf. To minimize lateral earth pressures and. prevent the buildup of <br />hydrostatic pressures, the backfill within 18 inche� ci the wsll should contain less than � percent <br />fines, based on that portion passing the U.S. No. �3 sieve. We a(so recommend constructine a <br />perforated footina drain placed at the base of the footing and �veep lioles on 3-foot centers diat <br />extend through the base of the wall. <br />The footing drain should consist of a minimum 4-inch diameter perforated pipe be <br />surrounded in at least 4 inches of clean, &ee-draining granular material, such as pea gravcl or <br />washed rock. A non-woven fil[cr fabric such as Mirafi 140N, or equivalent, should envelop tl�e <br />free-draining granular material. We rccommend that die diameter of the drainage materiaf be <br />greater than the diameter of [he pipe perforations. Footing drains should be directed toward <br />appropriate storm water drainage £acilities or to a suitable discliarge location (with quarry spall <br />erosion protection) near the base of the ravine. Roof or patio deck drains should not be <br />connected to the footing drains. <br />If the backfilled wall is structurally restrained from lateral movemcnt at the top, we <br />recommend that i[ be desigrted for an "a[-resP' equivalent fluid weight of» pounds per cubic <br />foot (pc fl. If the top of the wall is free to move laterally in an amount equal to at least 0.1 <br />percent of the wall heiglit during placement of backfill soils, it may be desi,;,�ed for an "activc" <br />equivalent (luid �veight of �0 pcf. <br />Surcharges due to sloping ground, adjacent foor'n�s, conswction equipment, etc., must <br />be added to these values. The above equivalent � uid pressures assume d�at the bac�ll is <br />compacted to approximately 90 to 92 percent of the modified Proctor maximum dry density. <br />Additional compaction adjacent to the ��rail will increase the earth pressure, whi:e c lesscr degree <br />of compaction could result in post construction settlements. <br />The fill nlaced upslope o£tl�e wall must be placed as strucrural lill th�[ is compacted to a <br />minimum of 90 percent of the modified Proctor maximum dry density. If d�e permanent fill is <br />placed on a slope that is stceper than SH:iV (20% or 1I degrees), it should be benched into <br />native soils of the underlying slope. We recommend that the hiilside 6enci�es wt into tl�e native <br />soil be at least one £oot in widtl�. <br />Construction Considerations <br />The preliminary plans provided by Chopelas & Associates, Inc indicates that die face of <br />the concrete retaining wall will Ue located on the order of 2 to 11 feet from the exisring home and <br />patio foundations. Based on our expiorations, �ve anticipate that a subgrnde adequate to support <br />the proposed retaining wall to be on the order of 10 to 16 feet belo�v the [op of the existing <br />timber pile wall patio grade. The depth o: the existing foundations and the nature of the soils <br />supporting these foundations are currently unlmown. Based on the exploration data, it is our <br />opinion that the existing �vall backfill soils aad underlying colluvium represent a Type C soil, as <br />defined in the Washington Administration Code, that corresponds to a maximum temporary cut <br />18905 37itl Avenue \Va4 Suim 117 <br />1-I501 <br />7inoer Zem�n 4ssaciates. Inc. <br />Lynnwood, R'uhington 98016 <br />(Jzs) 771 —]lW � �. <br />� G� � <br />
The URL can be used to link to this page
Your browser does not support the video tag.