Laserfiche WebLink
10/24/1997 15:10 <br />Murray <br />Tobiasa <br />-� <br />Land Uae ,�lannir <br />Octobcr 24, 1997 <br />4253551307 <br />- <br />, Inc. <br />• Ci4it Engineedny • <br />Mr. Ken Sxvenaoa <br />do The Lemn ComP+mY� Inc. <br />P.O. Box 12863 <br />Mill CrceJc, WA 98082 <br />Pat�M Fax Noa <br />MJiRAY-TOBIA9DN, INC <br />�e�� <br />• t <br />Re: Revision to SLe�rwall of Two Story Re�idence LocAted xt <br />1518 W Mukilteo Boulevard� Ererott <br />Dear Ken: <br />PAGE 01 <br />?a34 <br />As discussed wich Mr. Tom Leron yesterday, the nquired sheurwall noted aa number "5" in the <br />gazngc along the den snd bath wall can be revix.d us foUows: <br />• Sheach the approximateiy 13 foot long den aide of this wall with 7/16" OSB per the shearwull S <br />_la,� consontction notes, instead of the garnge side as shcwn on the approved plans. A detail is <br />(/' a[cached for refem�ce. <br />�,�,(� �S • The sheathing must be nailed to the holdown studs at the garage roar wall intersection with the <br />O��,r�"�� den waU using 8 penny nnils at 3 inches on center. <br />• A deuul for connection between the new sheaiwall edge s[uds and shearwall "8" in the den is <br />�� shown on the attached sheot to provide �uate load transfer co the existing strap tle, which <br />eGminates the need to netrofit a holdown at th�s locadun, <br />• All ocher eonstcuction and connecdons are to br as noted on the approved plans. <br />If you have any ques[ions, please call. <br />Sincerely, <br />qA1�RRAY-TOBIASON� INI <br />John P. Vardanega, P.E. <br />Projcct Engincer <br />IPV/jpv: 2S3A Stcvcnsan 971024 <br />att:1c1U11Cl1[ <br />626 • 128th SfrEet Soulhwest, Suite 107 � Everett, Wushinqton 98204�6$'• Phone: 42&513•?500 • F.nt:425�3551307 <br />