Laserfiche WebLink
February 1, 1993 <br />R <br />�UBL/C I�I/O � <br />Donald Senter <br />3621 Shore Drive <br />Everett, Washington 98203 <br />RE: Owner: Donald Senter <br />Job AddrPss: 2129 Mukiiteo Boulevard <br />Plan Check No: 39195 <br />Dear Mr. Senter: <br />In response to your applicadon for a construction permit, your plans have been examined and you are <br />advised that the issuance of a.permit is being withheld for the reasons listed below. These commenu <br />address building issues only, add��onal revis�ons or additions may be required by other departments <br />(such as Utilities, Planning or Fire). All references refer to the 1991 Uniform Building Code, as <br />amended by the State of Washington and/or Washington State Energy Code 1991, 2nd Edi6on, unless <br />stated otherwise. <br />F <br />1. The proposed residence does not meet the prescripdve requirements for wind and seismic <br />� bracing as specified in SecUon 2517(g)3 of the Umform Building Code (UBC). Provide <br />structural analys�s prepazed by a licensed Washington State Structural engineer for wind and <br />seismic forces. <br />2, The actual percentage of glazing (21.5'%) exceeds the alllowable glazing percentage (21 �'o) <br />for the compl�ance path ind►cated on the plans. Provide new compliance path or submit a <br />component performance calculation to show compliance. Also, you may be elibible for a <br />payment from the electric utility if your house is heated with a heat pump and meets the more <br />stnngent electric resistance cod: requirements of the 1991 Washington State Energy Code. <br />3. Specify all post/beam posdfooting, beam�'beam connections. A positive connection is <br />required for uplift and iateral sypport per Section 2516(m) UBC. <br />4. T'he footing for the post in the garage is shown in a different locadon than is shown on the <br />floor plan. <br />5. Provide detail for comer window hrader support. <br />In ordcr for the processing of your application to condnue, it will be necessary to provide the Building <br />Division with two complete new sets of drawings reflecting the conections requested. <br />Upon resubmittal of the drawings, your application will be given priority and plan review <br />recommence. <br />All required submittals shall be of sufficient detail and contain suffic:ent information to ensure that the <br />proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />Jeff Heilman <br />Development Technician <br />)H:cglpl�nck-I <br />r.i7v C1F FVFRFTt• 3200 Cedar Street • Everett, WA 98201 •(206) 259-8800 • Fax (206) 259-8856 �' <br />