Laserfiche WebLink
��� <br />H <br />>HN <br />H�� <br />fC C] <br />pH� <br />'�tl H � tl <br />Hy <br />�HC <br />O I-i <br />��g <br />(7 Y (] <br />ry�H <br />gy <br />��w <br />�O� <br />0 <br />Plan Check No. 91/27175 (Continued) <br />Page 2 oc 2 <br />n <br />2. Foundation plan does not inSicate size of beam supporting Eloor <br />joists. IndicaCe size, species and grade of all beams. <br />3. Footings at 6X8 posts at garage are not big enough to support the <br />loads imposed. Provide new footing size and indicate any rebar (if <br />tequired), <br />4. BX10 D.F. #2 beam at garuge is overstressed in bending. Provide new <br />beam size, species and grade. <br />5. 6X18 D.F. #1 benm at garage is overstressed in bending. Provide new <br />beam size, species and grade. <br />6. Triple 2X10 II.F. #2 beam at sunken family room is oveist[essed in <br />bending and in shear. Provide new beam size, species and grade. <br />7 <br />All loads shall ba transEered to this foundation by means of solid <br />posts, multiple studs or bearing walls, there are several <br />�ahere significanc londs are not considered (such as, at tl <br />the 6eams in the garage). <br />8. Plans do not indicate header sizes. SpeciEy size, species <br />'�' � of all headers and beams. <br />'�/ 9. Provide details of posc and beam, beam to beam connection <br />connectors eo be used. <br />1 <br />' <br />/ '� <br />1 <br />� <br />� ��� �,-��;. <br />�� fi . <br />�. ���Tt',�?+,.� . <br />In order for the processing �f your applLcntion to continue, 1 <br />necessary to provide the Building Department with two co�oplece n� <br />drawings reflecting the corrections requested. <br />Upon resubmittal of the drawings, your application will be givei <br />and plan review Will recommence. <br />All of the above information shall be of sufficient detail ai <br />sufficient inEormation to ensure thac che proposed sctvcture <br />constructed in compliance with the City Building Code. <br />Seccions shall be applicable to plan subwitted. � <br />Slncerely, <br />Jeff fieilman <br />Engineering Technician <br />ati:� cb�ii-za <br />