Laserfiche WebLink
naa� o� s�� ro: <br />FRAMING PHASE <br />J <br />Ins ection A mved ✓ <br />Q 0 6. All structural panels <br />shall be labeled "EXP <br />� � 7• InsulaHon baffles sh <br />extend at least 6" ved <br />c <br />c. <br />ch as plywood, oriented strand board, par6icle b <br />URE I„ „EXT'ERIOR", OR HUD-APPROVED" ( <br />be placed in attics/ceilings m maintein at least 1 <br />Ily above baHs or 12" verticallv above loosefill u <br />S. <br />board <br />space <br />Q � 8. Glazing efficiency/ Maximum allowed glazing area Shall be as calculated on Glazing Sch� <br />and r Prescri tive O tions rorm or Cha ter 5 Trade -off calculation form. <br />� � 9• Concealed InaulaHon shall be placed: a) Behind shower/tub b) Behind partition shtds/< <br />� � 10. Standazd air leakage (S. 502.4.3) caulking is complete end ins4lled in the following locatic <br />a) Between Sole plate/subEloor d) Partition stud penetrations <br />b) Wiring/plumbing/ductregisterpe��etradons e) Lightfixture/fluepenetrations <br />c Rim 'oisls mud sills heated lower floors Around window and door frames <br />Q Q il. Recessed lighNng fixtures (S.502.4.4) shall comply w/one or more of ffie following: <br />a) IC raled, with no slots or holes in cans, caulked or sealed behveen can and ceiling. <br />b) IC rated with label certifying an ASTM E328 tested air leakage 5 2.0 CFM <br />e) Any UL listed fixture enclosed by a Ifi" gypboerd box or other manufactured box with �/i' <br />clearance to combustibles, and 3" clearance to uuulation. <br />V@ri�dtlOri Re(;il1I'eIll@rit8 f OT ITL(�OOI' i11I' Qlldll{� The Ventilation and Indoor Air <br />Quality Code (VIAQ) requires that residences be equipped with a means of exhausting pollufants ftom speciRc <br />locations. The VIAQ also requires the introduction of fresh air into bedraoms and other hebitabte snacr_s. <br />� � 12 Source SpeCifiC Exhaust Fan9: for all bathrooms and laundry areas shall be a minimum <br />of 50 CFM rated at .25 water gauge (w.g.) . Kitchen range hood shall be 100 CFM raMd at .10 w.g. <br />A Whole House Ventilation exhaust fan may double duty for bath or laundry fan provided it <br />meets whole house ventilation requirements. Exhaust fans must be ducted to terminate outdoors. <br />fan ducta shall be 2 <br />sized (VIAQ Table 3-3), k irtsulated to R-4. <br />O WHOLE HOUSE VENTTLATION - E7QiAUST OPTION <br />Install a 24 hour Hmer to control an exhaust fan. A dd,� �N .0 '7 so 1� <br />1.5 sone (quiet) exhauet fan sized (at .25 w.g.) as follows: <br />1•2 bedrooms: 50-75 CFM; 3 bedrooms: 80-120 CFM; <br />4 bedrooms: 100-150 CFM; 5 bedrooms: 120-180 CFM <br />FRESH AIR INLEI'S: are required for this option. Inlets are required in ell bedrooms and in <br />each habitable room (includes bedrooms,kiMt�en,etc., but not bathrooms or utilitv roomsl <br />I5. U WHOLE HOUSE VENTILATION - HVAC INTEGRATED OPI'ION <br />� � a) Install a 24 hour Hmer to control intake damper and fumace blower. <br />O O b) Inst�ll an automaHe (electric) damper in the outside air intake. Other devices , such as a <br />manual damper or automatic flow regulation device, are only allowed when: airflow is tested <br />or the device is uutalled as per manufacturers uutructions to ensure a whole house a'u <br />change rate behveen .35 and .5. <br />O O c) Install a outside air intake duct & connect to retum air plenum, within 4' of blawer and <br />sized as follows: <br />SMOOTH Duct Diameters•: 6" for 2 bedrooms; 7" for 3 bedrooms; 8" for 4 bedroams <br />•ADD 1" diameter - foz Flex duch for lengths over 20'; each elbow after 3rd elbow <br />NOT'E: The terminal element shall be same size as cannxtin¢ ductwork or 8", which �ver i� laz¢er <br />WSEC Framittg Phase Requiremenfs: <br />