My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1001 E MARINE VIEW DR 2018-01-01 MF Import
>
Address Records
>
E MARINE VIEW DR
>
1001
>
1001 E MARINE VIEW DR 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2018 7:51:31 AM
Creation date
2/26/2017 8:14:32 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
1001
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Washington State Energy Code: Component Performance Worksheet <br /> Zone 1, Electric Resistance <br /> Project Name: Vinlage al Everett-Building 10 Permit Applicanl: 7J Mellema <br /> Project Address: Easl Marine View Drive E�el Developmenl Group <br /> Ever 1. Add�ess: ?23 Telegraph Rd <br /> City, Stale, 7_Ip: Hellingham,WA 98226 <br /> �� ` ���� ���U' Phone: 360-734-2872 Fax: 360-671-7616 <br /> Form prepared by: R Sc 11 or u h <br /> DRS Energy Managemenl <br /> 1001 W Toledo, Bellingham,WA 98229 Jurisdiction: City of Riciiland,WA <br /> 360-G71-9390 <br /> Heating System Size <br /> Duc!i are located In unconditioned space.� <br /> Conditioned Floor Area <br /> 15063 Equipment size over design load tso�,� <br /> Conditloned Building Volume 135335 Dtu/hour oulput 160,711 <br /> Wcathcr Station Evcrett x _� KW 47'� <br /> Component Performance,Zone 1, Electric: Code Target Values Proposed pesign Values <br /> U-Factw Area UA Area UA <br /> Vertical Glazinc� 0.400 2z59 903.8 960 480.0 <br /> Overhead Glazing iutalled in Attres O.SSD 0 0.0 0 0.0 <br /> Overhead Glazing In:�tal/ed in Vaults 0.560 0 0.0 0 0.0 <br /> Doors 0.200 Z� 4•� 20 7.4 <br /> Attics D.031 3766 116.7 3766 57.9 <br /> Single Rafter/;oist Vaull 0.034 0 0.0 0 0.0 <br /> Wall(abr�ve grade) 0.058 �347 �8�1 2646 164.1 <br /> Floors 0.029 0 0.0 0 0.0 <br /> Slab 0.540 `�8 SZ�� 98 68.6 <br /> 8elow Grade Interlor <br /> 2'depth,wall 0.043 0 0.0 0 0.0 <br /> 2'depth,slab 0.690 0 0.0 0 0.0 <br /> 3.5'depth,wall 0.041 0 0.0 0 0.0 <br /> 3.5'deplh, slab 0.640 0 0.0 0 0.0 <br /> 7'depfh,wall 0.037 0 0.0 0 0.0 <br /> 7'depth, slab 0.570 0 0.0 0 0.0 <br /> Below Grade Exterior <br /> 2'depth,wall 0.070 0 0.0 0 0.0 <br /> 2'depth,slab 0.600 0 0.0 0 0.0 <br /> 3.5'depth, �vali 0.064 0 0.0 0 0.0 <br /> 3.5'depth,slab 0.570 0 0.0 0 0.0 <br /> 7'depth,wall 0.056 0 0.0 0 0.0 <br /> 7'deplh,slab 0.420 0 0.0 0 0.0 <br /> Target UA Tolal 1155.5 Proposed UA To�al 818.0 <br /> If the Propased UA 5 The Target�he UA requiremenls are meet. <br /> Check other code requiremenls <br /> Copyright 2002,WSUC[EP 02-047 (Version 2) <br /> Copied by permiscon froin Washington State University Cooperative Extension Energy Program. 6�2104 � of 4 <br /> (see copyright restriclions) <br /> � I <br />
The URL can be used to link to this page
Your browser does not support the video tag.