Browse
Search
534 E MARINE VIEW DR BELMONTE HEIGHTS WHOLE SITE 2016-01-01 MF Import
>
Address Records
>
E MARINE VIEW DR
>
534
>
BELMONTE HEIGHTS WHOLE SITE
>
534 E MARINE VIEW DR BELMONTE HEIGHTS WHOLE SITE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2017 10:26:39 AM
Creation date
2/26/2017 10:26:15 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
534
Tenant Name
BELMONTE HEIGHTS WHOLE SITE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c. Lanes without curbs shall be identified by red traffic paint with a 6inch wide stripe on the <br /> pavement,extending the lengih of ihe designated fire lane. <br /> d. The words 'NO PARKING-FIRE LANE'shall be in 3-incl� stroke white letters 18 inches in <br /> height, and placed 8 inches measured perpendicular from �.he red paint stripe on the pavement. <br /> In most cases, boUi sides of thc aceess road shall be marked. Where long drives are to be <br /> marked, the repetitions shall altemate sides of the drive. <br /> c. Marking shall also include the addition of inetal signs stating'NO PARKING-FIRE LANE� <br /> TOW AWAY ZONE' to bc installed at intervals or locations designated by the fire code <br /> official. The signs shall be approximately 12 inches in width and I S inches in height and have <br /> red letters on a whitc background. Metal signs shall be installed on either 2-inch metal pipes <br /> for private property or treated 4-inch by 4-inch wood posts for public property and shall be <br /> located so that the bottom of the sign is a minimum of 7 fcet abovc the curb. Where fire lanes <br /> are adjacent to buildings or stn�ctures and when approvec or directed by the fire code officiAl, <br /> thc signs may be placed on the face of the building or structure. <br /> f. Where directed by the fire code official, specific areas shall be designated and those azeas are <br /> to bc marked �viUi diagonal striping across the�vidth of the frc lane. Diagonal marking shall <br /> be uscd in conjunction with painted curUs and/or edge striping and shall run at an angle of 30 <br /> to 60 dcgrccs from one side to the otlicr. '1'hese diagonal lincs shall be in red tra�c paint, <br /> panllcl wilh each other, at Icast G inches in width and 24 inches apart. Lettcring sha(l appear <br /> as abovc. <br /> 5. Prcmisc Identification - Promises shall be cicarly idcntificd by tl�e correct address at the strect entry. • <br /> Buildings shall be cicarly identified so :ts to be visibfe and Icgibfe from the access road. Individual <br /> ap:vunents and suites, wl�c�c applicable,sliall be cicarly and Iegibly identified from lhe access road. <br /> G. PREMISI; IDGNTIFICATION ANll ALL RCQl71RED FIRE DEPAR7'MENT ACCESS <br /> ROADS AND FI1iG HYllRAN'1'S SHAI.L 13� IN S�IiVICG PRIOR TO COrIMENCEMENT <br /> Or CONSTRUC170N. <br /> 7. Sccuritv Fcnce- Any security icnce erected around Uie construction site shall be located so as to not <br /> oUstn�cl any c�isting hydrant, firc protection cquipmcnt, or Pirc nepartmcnt access. If Fire <br /> De�rutment access is obstn�cted, gates or other openings shall be provided for acccss. <br /> 8. A firc hydraut is required witliin 350 driving fcet of cvcry ono-or rivo-fatuily dwelling swcture. <br /> 9. Pire rlow- Minimun� firc Ilow requircmcnts for single and two-fvnily residences under 3600 square <br /> feet is ]000 gpm; over 3G00 sqii�re fccl, f re tlow is acwrding to 2003 Intemational Fire Codc, <br /> Appendi� B. <br /> 10. Pire Suppression (Snrinklcrl S��stem-An approved automatic suppression system shall be provided <br /> as rcquircd by City Ordivance No. 1902-92, CLaptcr 16.76, of Uie �verett Municipal Code. The <br /> systcm must includc a mcchunical ���:�tcr gong bcll. <br /> EXHIBIT # ` <br /> PAG E�pF�. <br />