My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
816 E MARINE VIEW DR 2016-01-01 MF Import
>
Address Records
>
E MARINE VIEW DR
>
816
>
816 E MARINE VIEW DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2017 10:47:16 AM
Creation date
2/26/2017 10:47:00 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
816
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�_ <br /> ,� <br /> 4. A firc hydrant is rcquircd within 200 driving fcet, but not cleser [han 50 feet, of evcry <br /> structure. Location of thc hydrant(s) shall bc approvcd by thc Pire Marshal. <br /> 5. Qased upon 7,792 square feet of 'I'ype V-I3, srrinklered consUvction, the fire ilow <br /> requircment is 1,500 gpm. <br /> G. Pire Alarm SVstem - An approvcu .�utomatic firc detection system shall be provided as <br /> mquircd by Ciry Ordinance Nu. 1902-92, Chaptcr 1G.76, of the Everett Municipal Code. Plans <br /> for such system shall be submitted to thc Pirc Marshal for rcvie�v and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended for usc. Appropriate trip <br /> tests, wiu�esscd by a Pirc Department inspector, shall bc performed, along with a ccrtificate of <br /> completion, prior to final acccptance of the system. �irc alarm systcros shall Ue installed <br /> according to NPPA Standazd 72. Install.ition of Crc alarm components, including basic <br /> ���iring, may not comntence bcfore plaus arc approved Uy tlie Fire Department Plan <br /> Revie�ver. I�ire alarm drawirgs must bc professionally rcndered, in suf�icient detail, and ntust be <br /> intcrnally consistcnt. Riscr diagrams must match installation plans and load calculations. <br /> Components must be listed and approved for use togetlicr. Changes to plans must include nc�v <br /> drawings and calculations and must be approved by ihe Pire Department Plan Revicwer prior :o <br /> installation. Pire alann installation is subjec[ to (ield inspection by a Fire Department Inspector. <br /> An approved set of plans and the [3uilding Deparuncnt electrical permit must bc present for any <br /> installation inspection. Fire alarm systems shall be installed under permit of the Ciry of Everctt <br /> I3uilding Department. Gleclrical inspections and approval are required prior to calling for <br /> acceptance tests. Call (425) 257-8510 for permit information. 1'he absence of ���orking phonc <br /> lines Pm• the alarm system will be cause for postpm�ing fire department inspection and testing <br /> and shall result in denial of occupancy. <br /> 7. Pire Sunnression (Sprinkler) Svstem - An approved a��tomatic suppre�sion system shall bc <br /> provided as required by City Ordinance No. 1902-92, Chapter 16.7G, of the E:erett Municipal <br /> Code. 7'he s��stem must include a mechanical «�ater gong Lell. Plans for any such system shall <br /> be submitted to thc Building Department for examination and approval. Such plans shall indude <br /> plans for thc undcrground mains diat will supply the sprinkler system. The ryn�- of sprinkler to be <br /> installed will be determined by the E3uilding Ofticial. It may be an NrPA 13, NFPA 13R, or <br /> NPPr� l3D systcm depending upon several factors. Sprinkler installation shall not begin without <br /> an approveu and stamped set oT plans from the Building Department. The Fire Department will <br /> �Qso review the plans and shall field inspect d�e installation based only on approveJ plans that must <br /> Uc on site. Changes to plans must be approved by both the Building and Fire Departments. <br /> AUoveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping sliall bc hydrostatically tested and flushed as cstablislied in NrPA Standard 24 <br /> for private fire mains. (Bclow-erowid pinina must bc iustalled Uv Washineton State Patrol <br /> Licensed Undereround Suriuklcr line certi�ed °U" installers. For further information, <br /> contact the State Fire Atarslial's OfCce at (360) 570-3134 or contact llie Everett Fire <br /> Department at (425) 257-8123.) All such tests shall be �vitnessed by a Fire Department <br /> iuspector. Call (425) 257-8124 to make an appoinnnent for inspection. Cor,tracwrs' materials and <br /> ,>\ <br /> ��j,S , <br />
The URL can be used to link to this page
Your browser does not support the video tag.