Laserfiche WebLink
. � ; <br /> i <br /> 7. Washington State �nergy Code Option III is for R-1 a R- occupancies only; <br /> please revise option for an R-3 occupancy and show cor ed U-value for i <br /> � windows. <br /> / � 8.J Please reference Section "B" on Sheet A-6 on the "Typical Exterior Wall <br /> L/ Section" for the placement and attachment of blocking at roof boundary. � <br /> 9. Insulate wall between addition and crawl space to R-21, fur-out wall as needed � <br /> for minimum 5 '/:" caviry. I <br /> 10. Provide note on drawings: verify minimum 50 cfin exhaust fan in existing <br /> bathroom. <br /> ✓I 1. Provide stringer size and quantity. Provide fireblocking along stringer at each <br /> stud space and at mid-run; show how stringer is attached to tloor at top. <br /> 12. Footings to rest on undisturbed soil not less than 18" below the finished grade; <br /> show on plans. <br /> 13. The plans show the lower level of the existing house as "existing family room"; <br /> there are no permits on record of creating living space in the lower level. The <br /> County records show this building as 1-srory and no basement. If there is work <br /> that has becn done without perm�ts m the lower level, it needs to be either (1) <br /> included in the permit or (2) returned to a crawl space (non-habitable). <br /> Plcase prepare a response Ietter showing where each item in this correction Ieher is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given prioriry and plan review will <br /> recommence. <br /> All required submittals shall be of sufficicnt detail and contain sufficient information to ensure <br /> that the proposed structum will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> �...��� ��.�� <br /> lorc 1►c[!,nan <br /> Dcvclopmcnt Technician <br /> 425-257-897G <br /> I:mail: jhcilman�n ci.evcmtt.wa.us <br /> ,�,.��,�.,,K,�„w.�,N�:-�������,.�����s„ �3 <br />