Laserfiche WebLink
Ltr. C. Dudiesne <br /> June 1G, 2006 <br /> Page 2 <br /> �;��� <br /> , 1 <br /> �'� 10. Provide 3" x 3" x �/," plate washer on al( anchor bolts in braced wall lines. Show on <br /> plans. <br /> r� 11. Provide G mil black vapor barrier in crawl space lap edges 12". <br /> O12. Specify footings to rest on undisturbed soil not less than 18" Uelow the finished <br /> grade. <br /> � 13. Provide moisture ba:ricr on exterior walls. <br /> :%� 14. Specify smoke alartns to be 110 volt and interconnected. <br /> � 15. Specify mininmm 50 cfin exliaust fan in bathroom and IaunJry room. Verify <br /> ventilation in existing bathroom. <br /> (_./ 16. Thc 4" x 12" x 18' Ueam in the living room appcars to be ovcrstressed. Provide new <br /> beam size, species and grade. <br /> � 17. Show nmltiplc swds or posls undcr point loads 1rom bc•ams. <br /> Please preparc a response Ictter sho���ing wliere cach item in tl�is correction letter is addressed <br /> on thc plan sct. <br /> Upon resul»niltal of thc drawings, your application �vill bc given prioriq� and plan review will <br /> rccommencc. <br /> All requimd submittals sliall bc of sufticient detail and contain sufficient information to ensure <br /> that the proposed stnicture will be construcled in compliance with all adopteJ codes. <br /> Sinccrcly, <br /> �� <br /> { <br /> Jct'f Hcilman <br /> llevelopment 'I'eclmician <br /> ; aia� <br /> i UCUIi`INfAnItilH�ll[II.AIAN:I'�vA5U70UlIJAlAP1.1:S11 . " <br />