Laserfiche WebLink
i I <br /> ,� r"`, <br /> Plan Check No. 55328 <br /> June 23, 1997 <br /> Fage 2 of 2 <br /> 7. Provide stair detail showing the following: <br /> a, handrai! size and location <br /> b. maximum rise, minimum run <br /> c. minimum width of 36" <br /> d. minimum headroom of 6'-8" <br /> e. spacing of intermediate baluster such that a 4" sphere cannot pass through <br /> , f, return handrail ro newel post, safety terminal or return to wall <br /> 8. Show how floor at new bedroom is ve:rtilated. Provide 1 square foot of ventilation for <br /> each 150 squaze feet of under-floor area. <br /> 9. Specify length of overhang(s) on elevation view(s). <br /> i <br /> I 10. Blocking is required at both ends of floor joists to resist overturning. Show blocking on <br /> sections and details. <br /> 11. Show how rafters over carport attach to wall at storage loft. <br />! 12. Specify framing at landing on stairs. <br />` <br />� Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> � recommence. <br />� All required submittals shall be of sufficient detail and contain sufficient information to ensure that <br />, the proposed swcture will be constructed in compliance with all adopted codes. <br />� Sincerely, <br />' <br /> I <br /> I Jeff Heilman <br />� Development Technician <br />�I ,H:��,,�ti.� <br />� <br />� <br />� <br /> r,.` - <br />�' <br />�,' " <br /> r,.�i"''� <br />