Geotechnical Engineering Eva."dtion <br />2109 McDougall Ave, Everett -Cobb <br />February 14, 2007 <br />RMI File No.34206 <br />Page 3 <br />lightlines leading to an appropriate collection and discharge point. Roof drains should be lightlined <br />separately of footing drains. All drainage should be routed to an appropriate discharge point. <br />Foundations <br />Conventional shallcw spread foundations should extend through any fill and should be placed on <br />undisturbed medium dense or better native soils. <br />Footings, including interior footings, should extend at least 18 inches below the lowest adjacent finished <br />ground surface for frost protection and/or bearing capacity and lateral resistance considerations. <br />Minimum foundation widths of 18 and 24 inches should be considered for continuous and isolated spread <br />footings, respectively. Standing water should not be allowed to accumulate in footing trenches. All loose <br />or disturbed soil should be removed from the foundation excavation prior to pouring of the concrete. <br />For foundations constructed as outlined above, we recommend an allowable design bearing pressure of <br />not more than 3,000 pounds per square fool (psi) be used for the footing design if footings are foundr ' on <br />the very dense unweathered till. if footings are placed on the weathered till the bearing pressure should <br />be restricted to 2000 psi. Current International Residential Code (IRC) guidelines should be used •vhcn <br />considering increased allowable bearing pressure for short-term transitory wind or seismic toads. <br />Potential foundation settlement using the recommended allowable bearing pressure is estimated to be less <br />than 1 inch total and 1/2-inch differential between adjacent footings or across a distance of about 25 feet. <br />Lateral loads may be resisted by friction on the base of the footing and passive resistance against the <br />subsurface portions of the foundation. A coefficient of Iriction of 0.35 may be used to calculate the base <br />friction, and should be applied to the vertical dead load only. Passive resistance may be calculated as a <br />triangular equivalent fluid pressure distribution. An equivalent fluid density of 200 pounds per cubic foot <br />(pef) should be used for passive resistance design. These recommended values incorporate safety factors <br />of 1.5 and 2.0 applied to the estimated ultimate values for frictional and passive resistance, respectively. <br />To achieve this value of passive resistance, the foundations should be placed "neat" (without fortis) <br />against the native medium dense or better soils or compacted soil should be placed against the faces of the <br />footing. We recommend that the upper foot of soil be neglected when calculating the passive resistance. <br />The soil surface should be horizontal in front of the footing for a distance equal to at least three limes the <br />depth of embedment of the footing. <br />RMI ASSOCIATES LLC (�' <br />