My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2109 MCDOUGALL AVE 2018-01-02 MF Import
>
Address Records
>
MCDOUGALL AVE
>
2109
>
2109 MCDOUGALL AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2022 8:16:10 AM
Creation date
2/26/2017 4:23:44 PM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
2109
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:NG/NEER/NG / PUBL/L SEMMES OEPARMENT <br />April 2, 2007 <br />Mr. Eric Cobb <br />2109 Mc Dougall Avenue <br />Everett, WA 98201 <br />Subject: Project: <br />Job Address: <br />Plan Check No: <br />Dear Mr. Cobb: <br />Cobb <br />2109 McDougall Avenue <br />C0702-033 <br />In response to your application for a construction permit, your plans have been examined and <br />you are advised that the issuance of a permi, is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />2003 International Residential Code, as amended by the State of Washington andror <br />Washington State Energy Code 2004 Edition, and adopted by the City of Everett, unless stated <br />otherwise. <br />In order for the processing of your application to continue, it will be <br />nceessary to provide the 13mlding Division with two complete new sets of <br />drawings reflecting the corrections requesta:I. <br />1. 2 x 4 over -framing at the cricket appears to be over spanned. Please verify span for <br />2 x 4 II.F. N2 rafters at 24" o.c. <br />2. Insulation baffle shall extend 6" vertically above Batts and 12" vertically above loose - <br />fill insulation. Show requirement on plats. <br />3. Provide smoke alarms per Section R313 in the existing house, and in new dining <br />room. <br />4. Show how existing roof rafters are supported over the stair opening. <br />5. Provide detail of guard. Show construction and requirements of Section R312. <br />6. Provide plan for basement. Designate the use of the space. 5�77,:�RA-6E <br />7. Provide minimum 3" x 3" x 114" plate washer on all anchor bolts in braced wall lines. <br />8. Engineering calls out 5/8" diameter anchor bolts at 24" o.c., the building section <br />shows 1/5" diameter A.B. at 5'-0" o.c. Please clarify. <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8656 22 <br />UIDI/PLNC1 WlII 11r]LH�h4tZAJ:D11 UIN Mr[XNR:eI L �%I 1 I I' / <br />
The URL can be used to link to this page
Your browser does not support the video tag.