Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br />4. Connect side sewer per City Standard #601. <br />5. Connect side sewer per City Standard #'s 601, 602, 604. <br />6. Connect all rooftop downspouts to the side sewer. <br />7. Connect rooftop downspouts to the drainage system provided for this lot. <br />8. Rooftop runoff must be discharged to a roof downspout �� ifiltration system per City of Everett Slorm <br />Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more detaiis. <br />11 <br />The contraclor must meet with the Public Works Inspeclor prior to <br />beginning the projec�Gall Randv Allen at 425-339-7403 I <br />ncN;�T-n+^ 1 <br />Install erosion control measures as determined by lhe Public Works inspector, such as silt fence, straw <br />bales, swales, or erosion blankets. <br />Install erosion control measures per City of Everett Standards for small parcels <br />12. Remove erosion control measures upon completion �f the r,roject prior lo final approval o( the permit. <br />Ies.��N k1.St $�%� <br />13. All excavated material fr shall be hauled to an approved, <br />permitted site. <br />16. <br />No dirt, mud, rocks cr debris to be tracked onto roadway. <br />No building materials to be stacked on sidewalk/roadway and sidewalk/roadway to be kept clean and <br />open for pedestrian travel. <br />Adjust water meter box 1" above side�valk grade. <br />17. Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan #'s 305A 8 306 on <br />this proposai's irontage as directed by lhe Public Works Inspector (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />18. <br />19. <br />20. <br />Install a Type I concrete driveway per City of Everett Slandard #307. <br />Pave driveway from lhe front property line out lo the street paving. <br />Pave to existing paving in alley. <br />21. Contact the _ <br />sewer services. <br />22 <br />23. <br />3! <br />Water District for connecting provisions for this buiiding's water and <br />A catch basin as per City Slandard Plan #402 with a gas trap per Standard P�an #410 is required for the <br />parking area. <br />If a sewer pump system is to be instalied, the pressure line must discharge into a private manhoie, then <br />gravity flow across lhe public right-of-way. <br />A sprinkler syslem is required for this building in compliance with the requirements of NFPA Standards <br />13D. <br />Plh'Comments I Revised 6i8111 <br />I� '( ' <br />